5 Installation at Site
18 of 32
Calio-Therm S NC/NCV
WARNING
Incorrect connection to the mains
Damage to the mains network, short circuit!
▷
Observe the technical specifications of the local energy supply companies.
1.
The pumps do not require any motor protection.
All pumps are designed for connection to 230 VAC 50/60 Hz and delivered with a
plug-type connection (supplied but not fitted) or integrated power cable with mains
plug depending on the version.
The power cable needs to be wired to the supplied plug.
After the cable/plug assembly has been completed, connect the plug to the
corresponding jack at the pump (IP42).
Table 7:
Power cable
Cable
Cable type
Outside diameter of the cable
5,5 - 10,0 mm
Outside diameter of the core (including
insulation)
2,95 mm max.
Cable cross-sections
0,75 mm
2
- 1,5 mm
2
massive or fine core cable
Connecting the cable at the pump
1.
Verify the supply voltage at the site against the data on the name plate of the
pump.
2.
Switch off the pump's power supply. Secure it against unintentional start-up.
Verify that the pump is de-energised.
3.
Strip the power cable as shown in the diagram.
At the cable to be inserted into the plug, strip about 24 mm of the sheath. Then
strip at least 12 mm of the insulation at each strand (see illustration).
24+/- 1.0
12+/- 1.0
Fig. 3:
Stripping the cable
4.
Remove the supplied plug-type connector from its packaging. Undo and remove
the screwed-on cable gland. Feed the stripped cable through the cable gland.
1
2
Fig. 4:
Plug-type connection
1
Strain relief device
2
Cable gland