A
Submersible mixer does not generate flow
B
Insufficient flow
C
Excessive current/power input
D
Vibrations and noise during mixer operation
Table 7:
Trouble-shooting
A B C D Possible cause
Remedy
-
✘
-
✘
Free-standing models: Submersible mixer has
been installed displaced by 180°; submersible
mixer is not seated on the supporting surface
of the submersible mixer stand.
Check installation. Install in correct flow direction.
-
-
-
✘
Free-standing models: Severe oscillation of
the free-standing guide rail as a result of
incorrect floor mounting
Check and correct; tank needs to be drained.
-
-
-
✘
Incorrect floor mounting
Check and correct; tank needs to be drained.