5
Installation at Site
5.1
Safety regulations
DANGER
Improper installation in potentially explosive atmospheres
Explosion hazard!
Damage to the pump set!
▷
Comply with the applicable local explosion protection regulations.
▷
Observe the information given in the data sheet and on the name plate of the
pump set.
DANGER
Persons in the tank during pump operation
Electric shock!
▷
Never start up the pump set when there are persons in the tank.
WARNING
Impermissible solid objects (tools, screws/bolts or similar) in the pump sump/inlet tank
during pump start-up
Personal injury and damage to property!
▷
Check the pump sump/inlet tank for impermissible solid objects before flooding,
and remove, if necessary.
5.2
Checks to be carried out prior to installation
5.2.1 Checking the operating data
Before installing the pump set, verify that the name plate data matches the data
given in the purchase order and the site system data.
5.2.2 Preparing the place of installation
Place of installation for stationary models
WARNING
Installation on foundations which are unsecured and cannot support the load
Personal injury and damage to property!
▷
Make sure the foundation concrete is of sufficient strength (min. C25/30 to
DIN 1045).
▷
Make sure the foundation has set firmly before placing the duckfoot bend on it.
▷
Only place the duckfoot bend on horizontal and level surfaces.
▷
Refer to the weights given in the data sheet/name plate.
Any resonances at the usual excitation frequencies (1x and 2x rotational frequency,
rotational noise) must be prevented both in the foundation and in the connected
piping, as such frequencies may cause extreme vibrations.
1. Check the structural requirements.
All structural work required must have been prepared in accordance with the
dimensions stated in the outline drawing/general arrangement drawing.
Resonances
5 Installation at Site
20 of 78
Amarex KRT