3.
Remove screw plugs 903.01 and 903.02 with joint rings 411.01 and 411.02, and
drain off the lubricant.
4.
Close screw plug 903.02 again, fitting a new joint ring 411.02.
7.2.1.5.4 Refilling the lubricant
WARNING
Lubricants posing a health hazard
Hazard to persons and the environment!
▷
When refilling the lubricant take appropriate measures to protect persons and
the environment.
CAUTION
Lubricant level too high
Mechanical seal operation is impaired!
▷
Always place the submersible mixer in horizontal position (as shown) for
refilling the lubricant.
903.01
411.01
Fig. 9: Refilling the lubricant
✓
The submersible mixer has been positioned as shown.
✓
The screw plug 903.01 and joint ring 411.01 have been removed.
1.
Fill the lubricant through the lubricant filler opening until the lubricant
reservoir overflows.
2.
Close screw plug 903.01 again, fitting a new joint ring 411.01.
7.3 Drainage/disposal
WARNING
Fluids posing a health hazard
Hazard to persons and the environment!
▷
Submersible mixers used in fluids posing a health hazard must be
decontaminated.
▷
Collect and properly dispose of flushing liquid and any residues of the fluid
handled.
▷
Wear safety clothing and a protective mask, if required.
▷
Observe all legal regulations on the disposal of substances posing a health
hazard.
1.
Always flush the submersible mixer if it has been used for handling noxious,
explosive, hot or other hazardous fluids.
2.
Always flush and clean the submersible mixer before sending it to the
workshop.
Make sure to add a certificate of decontamination. (
⇨
Section 10 Page 52)
7 Servicing/Maintenance
Amamix