The submersible mixer is operational when the fluid level is not lower than
dimension W
T
. This minimum level of the fluid handled must also be ensured during
automatic operation.
D
W
T
h
1
h
2
Fig. 7: Minimum level of fluid handled
Table 6: Minimum level of fluid handled
Ø D
h
1 min
h
2 min
W
T min
[inch]
[mm]
[inch]
[m]
[inch]
[m]
[inch]
[m]
8
200
4
0.11
20
0.50
32
0.82
12
300
6
0.15
31
0.80
49
1.25
20
400
8
0.20
33
0.85
57
1.45
24
600
12
0.30
39
1.00
75
1.90
6.2.4.2
Fluid temperature
DANGER
Fluid temperature
Explosion hazard!
▷
Never operate the submersible mixer at fluid temperatures exceeding those
specified in the data sheet or on the name plate.
DANGER
Fluid temperature
Danger of frost/freezing!
▷
The submersible mixer is designed for operation in liquids. The submersible
mixer is not operational, and therefore must not be operated, under freezing
conditions.
6.2.4.3
Density of fluid handled
The power input of the submersible mixer increases in proportion to the density of
the fluid handled.
CAUTION
Impermissibly high density of the fluid handled
Motor overload!
▷
Observe the information on fluid density in the data sheet.
▷
Make sure the motor has sufficient power reserves.
6 Commissioning/Start-up/Shutdown
26 of 54
Amamix