11
10
1
A. Disconnect the water proof
connector between the battery
box and the electronic unit.
B. Pull out the battery box
from the battery box holder
by releasing the bottom clip.
C. Pull out the battery cover.
A
B
C
2
D. Replace the used battery
with a new 9V battery (Lithium
battery is recommended).
E. Close the battery box and
slide it back on the battery
holder starting from the
bottom upwards.
F. Connect the connectors.
D
E
F
3
IMPORTANT: Wait a few seconds before activating the product.
Close the battery compartment and refit the cover plate.
BaTTERy REPlacEMENT
When the battery weakens, the LED indicator light will blink at a constant
rate when the user’s hands are within the sensor range. The battery must be
replaced within two weeks.
To replace the battery at Biona battery version:
IMPORTANT: Spent batteries should not be disposed of with normal
household waste. Contact your local authority for information on waste
disposal and recycling.
MaINTENaNcE
FILTER CLEANINg INSTRuCTIONS
This faucet is provided with one stainless steel filter preventing foreign particles
to enter the lines. It is recommended to clean the filter every six (6) months. If the
water flow has decreased, this can be because the filter is clogged. The filter can
be cleaned as follows:
1. Shut-off the water shut off valve (angle valve).
2. Remove the filter located between the solenoid valve housing and the inlet
adapter \ shut off valve.
3. Wash the filter under running water.
4. Reassemble the parts.
5. Make sure that there is no water leakage.
CARE AND CLEANINg OF CHROME AND SPECIAL FINISHES
DO NOT use steel wool or cleansing agents containing alcohol, acid, abrasives, or
the like. use of any prohibited cleaning or maintenance products or substances
could damage the surface of the faucet. For surface cleaning of faucet use ONLY
soap and water, then wipe dry with clean cloth or towel. When cleaning bathroom
tile, the faucets should be protected from any splattering of harsh cleansers.
SOLENOID VALVE SERVICINg
The solenoid valve diaphragm requires periodical cleaning every six (6) months.
Remove the diaphragm from the solenoid valve and examine it for dirt. in case it is
dirty or clogged, wash it under running water and reassemble it.
Do not attempt to dismantle the solenoid valve if you are unfamiliar with electronic
solenoid valves.