*Copying schedules
Press
or
to choose
the
copy
parameter.
Confirm the settings by
pressing
Press
or
to choose
which day to copy parameter.
Confirm the settings by
pressing
Press
or
izberite
choose
paste�
Confirm the settings by
pressing
Press
or
to choose a
day.
Confirm the settings by
pressing
To return to the home screen
press
9 SCREED-DRYING PROGRAM
How to set and activate the screed-drying program is
described in the commissioning protocol. During com-
missioning the technician will set it, turn it on, adjust it
if needed, and explain the program to you.
10 ADDITIONAL HEATER
The KSM regulator allows for 2 additional heaters.
a)
Additional heater 1 is a built-in flow through electric
heater that is used if the heat pump has a fault or if
additional heat is needed to heat the system.
b)
Additional heater 2 is an external electric heater, oil
or gas heater that can but used as an additional heat
generator in the heating system.
An authorized commissioning technician sets the addi-
tional heater 1 and 2.
Manually turn on the additional heater in the shor-
tcut menu on the KT-2A or on the web and mobile
HomeCloud app. The additional heater turns on auto-
matically if needed.
In backup mode the additional heater 1 is turned on.
11 ANTI-FREEZING MODE
If there is a fault and the system is in standby mode,
the heat pump switches to anti-freezing mode. In this
mode water in the heating system is limited to the mi-
nimal temperature.
Additional heater 1 is always used in anti-freezing
mode.