B5U027115E
GEN2 M30 UHF Serial-J1939 Manual – Rev. 1.15
Page 25 of
51
Parameter
Description
•
0x02: Milller 4;
•
0x03: Miller 8.
Note that allowed values are:
R->T Link Frequency
R->T Bit Coding
40 kHz
FM0, Miller 2, Miller 4, Miller 8
160 kHz
FM0, Miller 2, Miller 4, Miller 8
256 kHz
Miller 4, Miller 8
320 kHz
Miller 4, Miller 8
640 kHz
Miller 4, Miller 8
DRM (Dense Reader Mode):
R->T Link Frequency
R->T Bit Coding
256 kHz
Miller 4, Miller 8
320 kHz
Miller 4, Miller 8
EPC Size
The size of the recognized EPC in bytes. 0 means all EPC sizes.
Use AFI
To enable/disable the AFI (Application Family Identifier) management:
0x00: Disabled;
0x01: Enabled.
AFI
The AFI (Application Family Identifier) value.
The parameters 1…14 fields with default values of page 0x82 are:
1
2
3
4
5
6
7
ReadAfterD
etect
Password0
ReadAfterD
etect
Password1
ReadAfterD
etect
Password2
ReadAfterD
etect
Password3
ReadAfterD
etect Bank
ReadAfterD
etect
Address0
ReadAfterD
etect
Address1
0x00
0x00
0x00
0x00
0x00
0x00
0x00
8
9
10
11
12
13
14
ReadAfterD
etect
Address2
ReadAfterD
etect
Address3
ReadAfterD
etect
Length
ReadAfterD
etect Info
Flags
Q
Q Adjust
Rounds
Inventory
Cycles
0x00
0x00
0x00
0x03
0x05
0x03
0x03
Where: