KRONE Medium Operation Panel
113
Pos: 32.51 /Ü berschriften/Ü berschriften 2/P-T/SSensor en Ballenfestig kei t testen_für Bedi enbox @ 329\mod_1426854325089_78.docx @ 2520039 @ 2 @ 1
7.8
Testing Sensors for Bale Firmness
Pos: 32.52 /BA/Bedienung /R undballenpr esse/Bedienbox Medium_F ortima/Sensortest Ei nführ ung _Text_F orti ma F @ 329\mod_1427180128647_78.docx @ 2521665 @ @ 1
If the baling pressure is not correct, the following sensors must be tested for proper function:
– Sensor on right for bale firmness
– Sensor on left for bale firmness
Pos: 32.53 /BA/Bedienung /R undballenpr esse/Bedienbox Medium_F ortima/Sensortest_Bil d_Forti ma F @ 329\mod_1427125774744_78.docx @ 2521229 @ @ 1
FOR00077
1
2
3
4
Fig. 76
Pos: 32.54 /BA/Bedienung /R undballenpr esse/Bedienbox Medium_F ortima/Sensortest Ballenfestig kei t_T ext_F orti ma F @ 329\mod_1427125775422_78.docx @ 2521260 @ @ 1
Sensor on right for bale firmness
• Raise the baling pressure indicator (1) on left at front side of round baler.
The warning light (4) must go out.
If the warning light (4) does not go out:
• Set sensor on right for bale firmness, refer to chapter Maintenance - “Setting the Sensors”.
Sensor on left for bale firmness
• Raise the baling pressure indicator (2) on left at front side of round baler.
The warning light (3) must go out.
If the warning light (3) does not go out:
• Set sensor on left for bale firmness, refer to chapter Maintenance - “Setting the Sensors”.
Pos: 33 /Layout M odul e /---------------Seitenumbruch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1