Start-up
40
Pos: 59.13 /Überschriften/Überschriften 3/F-J/Hydraulikleitungen anschließen @ 0\mod_1199777037794_78.docx @ 34244 @ 3 @ 1
7.3.3
Connecting the hydraulic lines
Pos: 59.14 /BA/Sicherheit/Hydraulik/WARNUNG - Vertauschen der Hydraulikkleitungen, wenn EW @ 9\mod_1220871857985_78.docx @ 128182 @ @ 1
Warning - If the hydraulic hoses are interchanged when connecting them to the
hydraulic system of the tractor, the functions will be interchanged as well.
Effect: Injuries, serious damage to the machine
•
Identify the hydraulic connections.
•
Always ensure correct connection between the machine and the tractor.
•
When engaging the hydraulic hose, the hydraulic control unit must be in float position or in
"lowering" position.
Pos: 59.15 /BA/Sicherheit/Hydraulik/Achtung - Verschmutzung der Hydraulikanlage @ 2\mod_1202393336803_78.docx @ 59155 @ @ 1
Caution! - Soiling of the hydraulic system
Effect: Damages to the machine
•
When connecting the quick couplings, ensure that these are clean and dry.
•
Note chafing areas or points of contact.
Pos: 59.16 /BA/Inbetriebnahme/EasyCut/Hydraulik/Hydraulikanschluss Bild EC B 1000 @ 97\mod_1329400010401_78.docx @ 878667 @ @ 1
Fig. 15
Pos: 59.17 /BA/Inbetriebnahme/EasyCut/Hydraulik/Hydraulikschläuche ankuppeln Traktor mit Load-Sensing Pumpe und Meldeleitung (LS) @ 98\mod_1329402554713_78.docx @ 878697 @ @ 1
Tractor with load-sensing pump and signal line (LS):
•
Connect the pressure hose (P) to the Load Sensing connector on the tractor.
•
Always connect the return flow to the connector for pressureless return flow.
•
Connect the signal line (LS) to the connector for Load Sensing control.
Pos: 59.18 /Abkürzungen /Abkürzungen Beschreibung/oder @ 102\mod_1331035559661_78.docx @ 902093 @ @ 1
or
Pos: 59.19 /BA/Inbetriebnahme/EasyCut/Hydraulik/Hydraulikschläuche ankuppeln Traktor mit Konstant-Druckpumpe @ 102\mod_1331035394077_78.docx @ 902067 @ @ 1
Tractor with constant pressure pump:
•
Connect the pressure hose (P) to the tractor.
•
Always connect the return flow to the connector for pressureless return flow.
•
Hang up the signal line (LS) on the holder on the machine.
Pos: 59.20 /Abkürzungen /Abkürzungen Beschreibung/oder @ 102\mod_1331035559661_78.docx @ 902093 @ @ 1
or
Pos: 59.21 /BA/Inbetriebnahme/EasyCut/Hydraulik/Hydraulikschläuche ankuppeln Traktor mit Konstant-Strompumpe (EW) @ 102\mod_1331035344580_78.docx @ 902039 @ @ 1
Tractor with constant flow pump:
To operate the machine, the tractor must be equipped with a single-action control unit with free
return flow to control the hydraulic system.
•
Remove the hydraulic coupling and plug supplied as standard.
•
Mount the components supplied (2x hydraulic plugs) on the hydraulic hose lines (P, T).
•
Connect the hydraulic hose line to a single-action control unit on the tractor.
•
Always connect the return flow to the connector for pressureless return flow.