Maintenance – electrical system
212
Pos: 112 /Überschriften/Überschriften 3/A-E/E/Einstellung der Sensoren @ 0\mod_1199962173428_78.docx @ 37635 @ 3 @ 1
21.1.1
Adjusting the Sensors
Pos: 113 /BA/Wartung/Sensoren/Namursensor d = 12 mm @ 0\mod_1199962247038_78.docx @ 37654 @ 4 @ 1
21.1.1.1
Namur sensor d = 12 mm
a
BP-VFS-088-1
2
1
3
Figure 139
The dimension between the encoder (2) and the sensor (1) must be "a" = 2 mm
.
Setting
•
Loosen the nuts on either side of the sensor.
•
Turn the nuts until dimension "a" = 2 mm
is reached.
•
Tighten the nuts again.
Pos: 114 /BA/Wartung/Sensoren/Anzugsdrehmoment Namursensor 10 Nm @ 101\mod_1330933143264_78.docx @ 899752 @ @ 1
The tightening torque for all Namur sensors is 10 Nm.
Pos: 115 /BA/Wartung/Sensoren/Namursensor d = 30 mm a= 4mm @ 101\mod_1330933066304_78.docx @ 899724 @ 4 @ 1
21.1.1.2
Namur sensor d = 30 mm
a
BPXC0172
2
1
3
Fig. 140
The dimension between the encoder (2) and the sensor (1) must be "a" = 4 mm.
Setting
•
Loosen the nuts on either side of the sensor.
•
Turn the nuts until dimension "a" = 4 mm
is reached.
•
Tighten the nuts again.
Pos: 116 /BA/Wartung/Sensoren/Anzugsdrehmoment Namursensor 10 Nm @ 101\mod_1330933143264_78.docx @ 899752 @ @ 1
The tightening torque for all Namur sensors is 10 Nm.