Maintenance
315
Pos: 59.158 /Überschriften/Überschriften 3/F-J/Hydrauliktank @ 76\mod_1309955430793_78.docx @ 665755 @ 33 @ 1
13.18.3
Hydraulic Tank
Pos: 59.159 /BA/Wartung/Umwelt/Hinweis Entsorgen / Lagern von Öle und Ölfilter Umwelt @ 32\mod_1253101375171_78.docx @ 311770 @ @ 1
ENVIRONMENT! - Disposal and storage of used lubricants and oil filters
Effect: Environmental damage
Store or dispose used oil and oil filters according to statutory provisions.
Pos: 59.160 /BA/Wartung/Rundballenpresse/Hinweis Hydraulikölwechsel @ 60\mod_1298295953433_78.docx @ 564922 @ @ 1
Note
Check the hydraulic oil level when the hydraulic oil is warm. When checking the oil level, the
tailgate must be closed and the bale lifting device must be located in the lower position.
•
Before refilling, clean the area around the filling plug (2).
Pos: 59.161 /BA/Wartung/Rundballenpresse/Ölsorten und Bezeichnung @ 76\mod_1309958943776_78.docx @ 665865 @ @ 1
Filling quantity and oil designation:
Comprima
Designation/Brand
Bio-
degradable
lubricants
Hydraulic
tank
CF155 XC
CV150 XC
CV210 XC
27 l
47 l
HLP ISO-VG 46 (initial
equipment)
HVLP ISO-VG 32/46
HEES 46 (bio-degradable very
quickly)
on request
Pos: 59.162 /BA/Wartung/Rundballenpresse/Hinweis Mischen von Ölsorten @ 60\mod_1298296505523_78.docx @ 564976 @ @ 1
(approx. 47 l)
Note
The types of oil must not be mixed! When changing, observe the VDMA guidelines!
•
Before refilling, clean the area around the filling plug (2)
Pos: 59.163 /Layout Module /---------------Seitenumbruch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1
Содержание Comprima CF 155 XC
Страница 383: ......