KRONE ISOBUS Terminal
161
Pos: 48.139 /BA/Info-Center/CCI-ISOBUS-Terminal/CCI-Press-Wickelvorrichtung/Hauptmenüs/Hauptmenü 4 Service/Menü 4-2 Sensortest Hand @ 53\mod_1289983643218_78.docx @ 507393 @ 33 @ 1
8.13.1
Menu 4-2 Manual sensor test
CC000289
CC000287
4-2
??
?
Fig. 122
In the manual sensor test, the sensors that are installed on the machine are checked for errors.
In addition, the sensors can be correctly adjusted in the manual sensor test. There is no
guarantee the machine is working correctly until after the sensors have been adjusted.
Caution!
The P.T.O. shaft must not be turning during the sensor test.
Calling the menu
Main menu 4 "Service" is called.
•
You can select menu 4-2
by pressing the function key
or
. The symbol is
highlighted in grey.
•
Press function key
.
Selecting the sensor
•
Select the sensor by pressing the function key
or
.
The selected sensor is displayed inversely and is tested.
Setting values:
The minimum and maximum setting values with the sensor alive (metal in front of the sensor)
are shown in the upper part of the bar display. The current setting value (actual value) is
displayed under the bar display.
The distance from the sensor to the metal must be adjusted so that in the alive state the bar is
in the upper mark. Next check whether the bar is in non-alive state in the lower marked area.
Pos: 48.140 /Layout Module /---------------Seitenumbruch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1
Содержание Comprima CF 155 XC
Страница 383: ......