dimension
a
[min.]
b
[min.]
c
20 mm 50 mm 20 mm
For an optimal combustion inside a
boiler, we recommend to insert a glow
pipe or mat.
Herewith we generate a hot burning
chamber
advantages:
-
Energie saving
-
better combustion
-
longer lifetime of the burner
Mounting:
Insert the glow pipe inside the burning
chamber, thereby the minimum dimensions mentioned
above have to be observed. The flame must be in the
middle of the glow pipe, therefor you must eventually base
the glow pipe with adequate, fire resistent material.
Insertion:
is recommended in cast iron boilers, where sometimes several flues are lead
out of the burning chamber.
The ceramic fibre board must cover the burning chamber bottom completely and
laterally be placed as high as possible. Pay attention, that the flues are not
covered.
ceramic fibre board
Ceramic fibre board
Glow pipe mounting
Glow pipe installation
41
Содержание KG/UB 100***P Series
Страница 6: ...Luft Öl Fließschema Air oil supply circuit Schéma d alimentation air huile 6 ...
Страница 11: ...Druck Leistungsdiagramm Pressure output diagram Pression puissance diagramme 11 ...
Страница 14: ...KG UB 20 KG UB 20 P Elektrodeneinstellungen Electrode adjustement Réglage l électrode KG UB 55 14 ...
Страница 15: ...Elektrodeneinstellungen Electrode adjustement Réglage l électrode KG UB 70 KG UB 100 KG UB 150 KG UB 200 15 ...
Страница 24: ...24 Schaltplan Circuit diagram Schéma électrique KG UB20 P KG UB 20 200 P ...
Страница 26: ...26 Einzelteile Component parts Nomenclature KG UB20 P KG UB 20 55 70 100 26 ...
Страница 29: ...29 KG UB150 KG UB200 Einzelteile Component parts Nomenclature ...
Страница 50: ...NOTIZEN 49 ...