Enclosed fibre mat
Installation
Combustion chamber with a convex rear panel
Combustion chamber with a vertical rear panel panel
Safety instruction:
If you do not need the mat, keep the bag closed or dispose it according to the
effective waste regulations.
The ceramic fibre mat must be put at the rear end of
each cast iron boiler.
The mat must be put on the floor of the boiler, raising to
the rear panel (see picture) in order to avoid creation of a
coating due to a drop shaped combustion.
The mat can be folded so that it fits into the combustion
chamber.
The remaining material can be cut off.
When you modify the ceramic fibre mat, make sure that
proper protection is guaranteed.
Combustion chamber - Ø at installation of
ZVP-tube min. 180 mm
**
marked measure are minimum size
KG/UB20-P = 20 mm
KG/UB20 + KG/UB55 =
25
mm
~10 mm
**260 mm
**30 - 10 mm
**KG/UB20-P = min. 300 mm
**KG/UB20 = min. 320 mm
**KG/UB55 = min. 360 mm
The ceramic fibre mat is adapted to the
convex rear panel of the combustion
chamber
Put the ceramic fibre plate
(039363) at the rear of the
combustion chamber
Put the ceramic fibre plate
on the floor of the ceramic fibre plate
37
Содержание KG/UB 100***P Series
Страница 6: ...Luft Öl Fließschema Air oil supply circuit Schéma d alimentation air huile 6 ...
Страница 11: ...Druck Leistungsdiagramm Pressure output diagram Pression puissance diagramme 11 ...
Страница 14: ...KG UB 20 KG UB 20 P Elektrodeneinstellungen Electrode adjustement Réglage l électrode KG UB 55 14 ...
Страница 15: ...Elektrodeneinstellungen Electrode adjustement Réglage l électrode KG UB 70 KG UB 100 KG UB 150 KG UB 200 15 ...
Страница 24: ...24 Schaltplan Circuit diagram Schéma électrique KG UB20 P KG UB 20 200 P ...
Страница 26: ...26 Einzelteile Component parts Nomenclature KG UB20 P KG UB 20 55 70 100 26 ...
Страница 29: ...29 KG UB150 KG UB200 Einzelteile Component parts Nomenclature ...
Страница 50: ...NOTIZEN 49 ...