8
TECHNICAL DATA
78
H250 M40
www.krohne.com
03/2020 - 4000640706 - MA H250-M40 R06 en
Pressure
Pressure
Pressure
Pressure
Max. operating pressure PS, max. test
pressure PT
Depending on the version (refer to nameplate)
Min. required operating pressure
2 times greater than pressure loss (refer to measuring ranges)
Pressure tightness (vacuum) H250/C
For detailed information refer to
Pressure tightness (vacuum) H250/C
on
page 81.
Pressure/temperature for the optional heating of the measuring cone
Pressure/temperature for the optional heating of the measuring cone
Pressure/temperature for the optional heating of the measuring cone
Pressure/temperature for the optional heating of the measuring cone
DN15...DN50
PS = 40 barg / 580 psig, TS = 300
°
C / 572
°
F
DN80...DN100
PS = 25 barg / 363 psig, TS = 300
°
C / 572
°
F
Ingress protection
Ingress protection
Ingress protection
Ingress protection
M40, M40R
IP66/68 according to EN 60529, NEMA 4/4X/6 according to NEMA 250
M40R
IP69K according to DIN 40050-9
Float damping during gas measurement recommended
Float damping during gas measurement recommended
Float damping during gas measurement recommended
Float damping during gas measurement recommended
DN15...25 / 1/2...1"
Operating pressure <0.3 barg / 4.4 psig
DN50...100 / 2...4"
Operating pressure <0.2 barg / 2.9 psig
Installation conditions
Inlet section
≥
5 x DN
Outlet section
≥
3 x DN
Note: Straight inlet and outlet sections are not required for accuracy
reasons, but may reduce instable flow indication caused by fluctuating flow
profiles and may increase lifetime because of reduced mechanical wear.
It is recommended to consider the inlet / outlet sections especially for
devices
≥
DN50 / 1".
Protect devices from vibration and high-
frequency oscillation
Use in accordance with IEC 61298-3 in control room or field with medium
vibration level.
Materials
H250/RR
H250/RR
H250/RR
H250/RR
Flange & measuring tube
CrNi steel 1.4401 / 1.4404, 316 / 316L (dual certification)
Float & float guide
1.4404, 316L
H250/HC
H250/HC
H250/HC
H250/HC
Flange
Hastelloy
®
C4 (2.4610) solid or plated
Measuring tube, float & float guide
Hastelloy
®
C4
H250/F - Food
H250/F - Food
H250/F - Food
H250/F - Food
Flange & measuring tube
CrNi steel 1.4435
Float & float guide
CrNi-steel 1.4435 / 1.4404
H250/C - Ceramic/PTFE (DN100 / 4" only PTFE)
H250/C - Ceramic/PTFE (DN100 / 4" only PTFE)
H250/C - Ceramic/PTFE (DN100 / 4" only PTFE)
H250/C - Ceramic/PTFE (DN100 / 4" only PTFE)
Flange & measuring tube
CrNi steel 1.4571 with TFM/PTFE
TFM/PTFE liner (electrically non-conductive), conductive PTFE on request
Float
PTFE or Al
2
O
3
with FFKM gasket
Float guide
Al
2
O
3
and PTFE
Ring orifice
Al
2
O
3