8
TECHNICAL DATA
24
BM26A-5000
www.krohne.com
01/2021 - 4008339901 - HB BM26A-5000 R01 en
8.2 Technical data
INFORMATION!
•
The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local sales office.
•
Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Downloadcenter).
PN40 /
Class 300
PN100 /
Class 600
PN250 /
Class 1500
PN400 /
Class 2500
Measuring system
Measuring principle
Bypass chamber for level transmitter (principle of communicating vessels). For
more data about the measuring principle, refer to the handbook of the level
transmitter option.
1
Application range
Level and interface measurement of liquids
Measured value
Measured value
Measured value
Measured value
Primary measured
value
Distance. For more data about the primary measured value, refer to the
handbook of the level transmitter option.
1
Secondary measured
value
For more data about the secondary measured value, refer to the handbook of
the level transmitter option.
1
Design
Bypass chamber,
variants
Side / side process connections
2
Level transmitter,
options
OPTIFLEX 7200 guided radar (TDR)
OPTIFLEX 8200
guided radar
(TDR)
BW25
displacer-type
OPTIFLEX 8200 guided radar (TDR)
OPTIWAVE 7400 24GHz FMCW radar
BW25
displacer-type
BW25 displacer-type
Other options
Thermal insulation (ROCKWOOL
®
or FOAMGLAS
®
) in a metal enclosure
Electric heat tracing system
Heat protective enclosure (metal grid)
Measuring range (ML)
0.3...5.5 m / 1
…
18 ft (longer on request)
Display and user interface
Display and user interface
Display and user interface
Display and user interface
Display
For more data about the display options, refer to the handbook of the level
transmitter option.
1
Measuring accuracy
Level transmitter
Refer to the handbook of the level transmitter option
1
Operating conditions
Temperature
Temperature
Temperature
Temperature
Process temperature
-196...+400
°
C / -320.8
…
+752
°
F
(refer also to the handbook of the level transmitter option)
1
Ambient temperature
-70...+80
°
C / -94...+176
°
F
(refer also to the handbook of the level transmitter option)
1
Storage temperature
-70
…
+80
°
C / -94
…
+176
°
F