DEVICE DESCRIPTION
2
11
BM26A-5000
www.krohne.com
01/2021 - 4008339901 - HB BM26A-5000 R01 en
The temperature and pressure range of a level transmitter installed on a bypass chamber is:
The bypass chamber can be made of:
•
316/316L (1.4401/1.4404) stainless steel,
•
304L (1.4307) stainless steel with >9.5% nickel content,
•
HASTELLOY
®
C-276 alloy (2.4819), or
•
INCONEL
®
nickel-chromium alloy 625 (2.4856)
Figure 2-2: Level transmitter options
1
Bypass chamber with BW25 displacer-type level transmitter
2
Bypass chamber with OPTIFLEX 7200 C TDR (Guided Radar) level transmitter
3
Bypass chamber with OPTIFLEX 8200 C TDR (Guided Radar) level transmitter
4
Bypass chamber with OPTIFWAVE 7400 C 24 GHz FMCW radar level transmitter
Device
Temperature range
Pressure range
[
°
C]
[
°
F]
[barg]
[psig]
BW25
-40...+400
-40...+752
-1...400
-14.5...5802
OPTIFLEX 7200
-50...+250
-58...+482
-1...100
-14.5...1450
OPTIFLEX 8200
-50...+315
-58...+599
-1...320
-14.5...4641
OPTIWAVE 7400
-50...+200
-58...+392
-1...100
-14.5...1450
Table 2-1: Bypass chamber with a level transmitter option: pressure and temperature ranges
INFORMATION!
For more data about the level transmitter options, refer to the related handbook (BW25,
OPTIWAVE 7400, OPTIFLEX 7200 or OPTIFLEX 8200).