7.
Check the seals (Fig. 13/1 to 6) for damage, replace if necessary.
Attaching the fluid needle
Fig. 14: Attaching the fluid needle
1.
2.
Push the fluid needle (Fig. 14/3) and spring (Fig. 14/2) into the valve shaft pipe (Fig. 14/4).
3.
Screw the nut (Fig. 14/1) onto the valve shaft pipe (Fig. 14/4).
Fig. 15: Attaching the fluid needle
4.
Push the entire valve shaft (Fig. 15/3) into the main element (Fig. 15/4).
5.
Attach the spring (Fig. 15/2) and tighten it with the entire closing piece (Fig. 15/1).
Operating instructions
T-Dok-144-GB-Rev.1
[email protected], www.krautzberger.com
GB–28