5.6
Checking connections
1.
Disconnect spray medium supply.
Fig. 7: Checking closures
2.
3.
One turn of the needle stroke adjustment moves the needle by 1 mm and corresponds
to 18 positions.
ð
No air may escape from the automatic spray gun.
4.
Open the control air.
ð
The needle of the fluid nozzle must push itself back and air must escape from the air
nozzle.
5.
Close the control air again.
6.
Establish fluid supply.
ð
No spray fluid may escape from the spray gun.
Automatic spray gun A-14
ENGLISH
■
200-0151
GB–19