
65
Checklist:
L.p.
Zakres
Czynności
1
General
inspection
Perform lighting a fi e in the stove.
Check the operation of all safety systems.
Check that the main burner flame bu ns steadily.
Check that the main burner flame bu ns evenly.
Check the batteries in the receiver and the remote control do not
need to be replaced.
Check the operation of all modes in the control unit.
2
Glass inspection
Make sure that the glass does not have any cracks Make sure the
glass fits tig t to the body of the stove.Check the wear of the glass
sealing cords. If necessary, replace the sealing cords.
Check the degree of dirtiness of the glass. If necessary, clean the
glass.
3
Switch box
inspection
Check the tightness of gas connections.
Make sure the switch box has adequate ventilation.
Check that the cables connecting the controller to the receiver are
not damaged.
Make sure gas control system components are not exposed to high
temperatures.
Make sure that the switch box is not exposed to moisture. Check that
the connecting cords have no signs of corrosion.
4
Combustion
chamber
inspection
Make sure the control burner is not obscured by decorative elements.
Check if the thermocouple is within the control flam . Check whether
the combustion chamber requires cleaning.
Make sure all air inlets to the combustion chamber are clear. If neces-
sary, clear the openings.
Check the tightness of the body of the stove.
Check the combustion chamber with respect to any signs of
corrosion. If necessary, remove corrosion and cover losses with a new
coating of paint. Check that the main burner ignites smoothly.
5
Control of the
chimney system
If possible, check the tightness of the chimney system. Check the
coaxial combustion air system patency.
6
Control device
inspection
Check that the receiver antenna is not damaged. Make sure that the
main valve knob and the manual mode dial work correctly.
Check if there is no insulation damaged in the circuits. Make sure the
AC power cord is not damaged. Make sure that the control system
components are not exposed to overheating.
7
Trim inspection
Make sure the gas stove trim has no cracks.
Make sure that combustible elements are at a safe distance from the
stove trim.
8
Decorative
elements
Make sure that decorative elements do not require cleaning.
Make sure decorative elements are not in contact with the glass.
Make sure that decorative elements are not damaged.
Содержание PANTHER MERLOT
Страница 4: ...4 Fig 1 PANTHER MERLOT estufa de gas Fig 2 Dimensiones estufa a gas PANTHER MERLOT ...
Страница 12: ...12 Fig 10 Desmontaje de las puertas Fig 9 Retirada de la cubierta inferior ...
Страница 39: ...39 Rys 1 PANTHER MERLOT GAZ gas stove Rys 2 Dimensions Freestanding PANTHER MERLOT EN ...
Страница 47: ...47 Figure 10 Removal of the doors Figure 9 Removal of the bottom cover ...
Страница 50: ...50 Fig 12 How to install a settler if required ...
Страница 72: ......
Страница 74: ...74 Fig 1 PANTHER MERLOT GAZ à gaz Fig 2 Dimensions du chauffage à gaz PANTHER MERLOT ...