54
55
Inspection result (check)
The high-pressure cleaner was checked by an expert according to the
Guidelines for Liquid Spray Equipment, the defects found have been rectified
so that the Labour Safety can be confirmed.
The high-pressure cleaner was checked by an expert according to the
Guidelines for Liquid Spray Equipment. The Labour Safety cannot be
confirmed unless the defects found are rectified by repair or replacement
of the faulty parts.
Scope of inspection o.k.
yes
no
repaired
Type plate (on hand)
Operating manual (on hand)
Protective covering, Protective device
Pressure line (tightness)
Stainless steel pressure gauge (function)
Float valve (tightness)
Spraying device (marking)
High-pressure hose / connector (damage, marking)
Safety valve opens at 10 % / 20 % exceeding
Pressure reservoir
Heating oil line (tightness)
Solenoid valve (function)
Thermostat (function)
Flow controller (function)
Power supply cable (damage)
Power plug (damage)
Protective conductor (connected)
On / Off switch
Water quantity safety device (function)
Used chemicals
Allowed chemicals
The next retest according to the Guidelines for Liquid Spray Equipment has to be
carried out by: Month .................................................... Year ........................................................
Place, Date ..........................................................Signature ...............................................................
High-pressure cleaners for industrial use have to be checked by an expert every
12 months!
Inspection report on annually carried out Labour Safety Inspection
(UVV) according to the Guidelines for Liquid Spray Equipment. (This inspection
sheet serves as proof for the completion of the retest and must be kept carefully!)
Kränzle-test seals: Item no.: UVV200106
Inspection data
determined value
set value
High-pressure nozzle
Operating pressure ..................bar
Switch off pressure .................bar
Smoke spot number ............................acc. to Bacharach scale
CO
2
-value ............................. % CO
2
Efficiency rating ..................... %
Protective conductor resistance not exceeded/value
Insulation
Leakage current
Safety trigger gun locked
Owner:
.................................................................................
Address:
...............................................................................
.....................................................................................................
Type:
.......................................................................................
Serial no.:
.............................................................................
Repair order no.:
.............................................................
Inspection reports
Inspection reports
Содержание therm 1165-1