46
WP-5VH2 - Protocol 3000
Command -
AUD-LVL
Command Type - Audio
Command Name
Permission
Transparency
Set:
AUD-LVL
End User
Public
Get:
AUD-LVL?
End User
Public
Description
Syntax
Set:
Set audio level in specific amplifier stage
#
AUD-LVL
␠
stage, channel, volume
␍
Get:
Get audio level in specific amplifier stage
#
AUD-LVL?
␠
stage, channel
␍
Response
~nn@
AUD-LVL
␠
stage, channel, volume
␍␊
Parameters
stage
- ‘IN, ’OUT’ or numeric value of present audio processing stage
For example: ‘1’ for input level, ‘2’ for output
channel
- input or output number
volume
- audio parameter in Kramer units, minus sign precedes negative values.
++ increase current value,
-- decrease current value
Response Triggers