Kramer Electronics Ltd.
VS-88H2A
– Technical Specifications
58
Default Communication Parameters
RS-232
Baud Rate:
115,200
Data Bits:
8
Stop Bits:
1
Parity:
None
Command Format:
ASCII
Example (Route input 1 to output 1):
#VID1> 1<cr>
Ethernet
To reset the IP settings to the factory reset values go to: Menu->Setup -> Factory Reset-> press Enter to
confirm
IP Address:
192.168.1.39
Subnet mask:
255.255.0.0
Default gateway:
192.168.0.1
Default TCP Port #:
5000
Default UDP Port #:
50000
Default username:
Admin
Default password:
Box left empty
Full Factory Reset
OSD:
Front panel buttons: power off the device, press and hold the LOCK, EDID
and STO buttons simultaneously for 3 seconds while powering the device,
and then release.
Protocol 3000:
“#factory” command.
Web Pages:
In the Device Settings page, click Reset.