VS-88FO

 - 

Kramer Protocol 2000

 

39

 

 

 

INSTRUCTION 

DEFINITION FOR SPECIFIC INSTRUCTION 

NOTE 

DESCRIPTION 

INPUT 

OUTPUT 

RESET DEVICE 

SWITCH VIDEO 

Set equal to video input which is to 

be switched 

(0 = disconnect) 

Set equal to video output which is 

to be switched  

(0 = to all the outputs) 

2, 15 

STORE VIDEO 

STATUS 

Set as SETUP # 

0 - to store  
1 - to delete 

2, 3, 15 

RECALL VIDEO 

STATUS 

Set as SETUP # 

2, 3, 15 

REQUEST STATUS 

OF A VIDEO OUTPUT 

Set as SETUP # 

Equal to output number whose 

status is required 

4, 3 

15 

REQUEST WHETHER 

SETUP IS DEFINED / 
VALID INPUT IS 
DETECTED 

SETUP #  
or  
Input # 
 

0 - for checking if setup is defined 
1 - for checking if input is valid 

16 

ERROR / BUSY 

For invalid / valid input (i.e. 

OUTPUT byte = 4 or OUTPUT byte 
= 5),  

this byte is set as the input # 

0 - error 
1 - invalid instruction 
2 - out of range 
3 - machine busy 
4 - invalid input 
5 - valid input 

9, 25 

30 

LOCK FRONT PANEL 

0 - Panel unlocked 
1 - Panel locked 

31 

REQUEST WHETHER 

PANEL IS LOCKED 

16 

56 

CHANGE TO ASCII 

– Protocol 3000l 

19 

61 

IDENTIFY MACHINE  

1 - video machine name 
3 - video software version 
 

0 - Request first 4 digits 
1 - Request first suffix 
 

13 

62 

DEFINE MACHINE  

1 - number of inputs 
2 - number of outputs 
3 - number of setups 

1 - for video 
3 - for SDI 
4 - for remote panel 
5 - for RS-422 controller 

14 

NOTES on the above table: 

 

NOTE 1

 - When the master switcher is reset, (e.g. when it is turned on), the reset code is sent to the 

PC. If this code is sent to the switchers, it will reset according to the present power-down settings. 
 

NOTE 2

 - These are bi-directional definitions. That is, if the switcher receives the code, it will perform 

the instruction; and if the instruction is performed (due to a keystroke operation on the front panel), 
then these codes are sent. For example, if the HEX code 
01  

85 

88  

83 

was sent from the PC, then the switcher (machine 3) will switch input 5 to output 8. If the user 
switched input 1 to output 7 using the front panel keypad, then the switcher will send HEX codes: 
41 

81 

87 

83 

to the PC. 
When the PC sends one of the commands in this group to the switcher, then, if the instruction is valid, 
the switcher replies by sending to the PC the same four bytes that it was sent (except for the first 
byte, where the DESTINATION bit is set high).   
 

NOTE 3

 - SETUP # 0 is the present setting. SETUP # 1 and higher are the settings saved in the 

switcher's memory, (i.e. those used for Store and Recall). 
 

NOTE 4

 - The reply to a "REQUEST" instruction is as follows: the same instruction and INPUT codes 

as were sent are returned, and the OUTPUT is assigned the value of the requested parameter. The 
replies to instructions 10 and 11 are as per the definitions in instructions 7 and 8 respectively. For 
example, if the present status of machine number 5 is breakaway setting, then the reply to the HEX 
code 
0B 

80 

80 

85 

would be HEX codes 
4B 

80 

81 

85 

 

NOTE 8

 - The reply is as in TYPE 3 above, except that here the OUTPUT is assigned with the value 

0 if the setup is not defined / no valid input is detected; or 1 if it is defined / valid input is detected. 
 

Содержание VS-88FO

Страница 1: ...KRAMER ELECTRONICS LTD USER MANUAL MODEL VS 88FO 8x8 3G HD SDI Fiber Optic Matrix Switcher P N 2900 300097 Rev 4...

Страница 2: ......

Страница 3: ...ds 25 6 3 Using the Infrared Remote Controller 25 6 4 Upgrading the Firmware 26 6 5 Changing the Device Parameters 26 7 Technical Specifications 27 8 Default Communication Parameters 28 9 Kramer Proto...

Страница 4: ...r in 11 groups that are clearly defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Routers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders an...

Страница 5: ...ality due to poor matching and elevated noise levels often associated with low quality cables Do not secure the cables in tight bundles or roll the slack into tight coils Avoid interference from neigh...

Страница 6: ...ected and recycled To comply with the WEEE Directive Kramer Electronics has made arrangements with the European Advanced Recycling Network EARN and will cover any costs of treatment recycling and reco...

Страница 7: ...Selectable sync signal termination Automatic reclocking and equalization Active input reporting where each input LED on the front panel automatically lights when the unit detects a video signal on tha...

Страница 8: ...onversions between optical and electrical signals The SFP transceiver is specified by the SFP Transceiver Multisource Agreement MSA which was developed and is followed by different transceiver manufac...

Страница 9: ...Section 5 4 6 OUT SELECT Buttons Select the output to which the input is switched pressing OUT 1 OUT 2 selects Protocol 2000 pressing OUT 1 OUT 3 selects Protocol 3000 7 STO STORE Button Pressing STO...

Страница 10: ...a microcontroller firmware upgrade RS 485 TERM DIP switch terminates the RS 485 line with a 120 load 20 RS 485 Terminal Block Port Pins B and A are for RS 485 Pin G may be connected to the shield if...

Страница 11: ...8 VS 88FO Installing in a Rack 4 Installing in a Rack This section provides instructions for rack mounting the unit...

Страница 12: ...0 and Class 1 per IEC 60825 1 are allowed in this product The following optional SFP modules are tested and approved for use with the VS 88FO SFP IN OUT 2KM SFP Fiber Optic Module SM 2km 3G HD SDI Tx...

Страница 13: ...The LOOP BNC connector to the GENLOCK connector of the next unit in the line and release the TERM button for looping Push in to terminate the input Release when the input extends to another unit 8 Co...

Страница 14: ...lot and push it inward until it clicks 3 Remove the protective SFP cap from the end of the SFP 2 To remove an SFP module 1 Pull the bail downward to release the SFP 3 2 Pull the SFP module out by the...

Страница 15: ...Each unit must be identified by a unique machine number MACH Determine the machine number according to the following table When using a single unit set the unit to Machine 1 A master unit must be Mac...

Страница 16: ...o update device firmware MACH 1 2 3 4 Self Address Sets the MACHINE see Section 5 2 1 The RS 485 TERM DIP switch is used only when the RS 485 port is connected see Section 5 3 The first and last units...

Страница 17: ...5 for each VS 88FO slave The units do not have to be sequentially numbered but they must have unique addresses 5 3 2 Setting the Line Termination To ensure correct operation the RS 485 line must be te...

Страница 18: ...or router using a straight through cable see Section 5 5 2 Note If you want to connect via a router and your IT system is based on IPv6 speak to your IT department for specific installation instructi...

Страница 19: ...Figure 6 Figure 6 Local Area Connection Properties Window 4 Highlight either Internet Protocol Version 6 TCP IPv6 or Internet Protocol Version 4 TCP IPv4 depending on the requirements of your IT syst...

Страница 20: ...VS 88FO Connecting the VS 88FO 17 Figure 7 Internet Protocol Version 4 Properties Window Figure 8 Internet Protocol Version 6 Properties Window...

Страница 21: ...rotocol Properties Window 7 Click OK 8 Click Close 5 5 2 Connecting the Ethernet Port via a Network Hub or Switch You can connect the Ethernet port of the VS 88FO to the Ethernet port on a network hub...

Страница 22: ...hernet configuration software from the Kramer Web site at http www kramerelectronics com Extract the file to a folder and create a shortcut on your desktop to the file To configure the Ethernet port 1...

Страница 23: ...he VS 88FO You can also connect to the PC using the Ethernet or a serial connector 4 Check USB as the connection method and select the COM port from the USB drop down list 5 Click Connect The K UPLOAD...

Страница 24: ...rnet configure the unit as master MACH 1 see Section 5 2 1 5 8 Using the Ethernet Reset Button To reset Ethernet parameters to the factory defaults 1 Turn the power switch OFF then while pressing the...

Страница 25: ...o its normal operating display 6 1 2 Using the AT ONCE and CONFIRM Modes Choose to work in either the AT ONCE or the CONFIRM modes In the AT ONCE mode pressing an OUT IN combination switches the unit...

Страница 26: ...the AT ONCE mode do the following 1 Press an OUT SELECT button from 1 to 8 or the ALL button The 7 segment display flashes 2 Press an IN SELECT button from 1 to 8 or the OFF button for immediate switc...

Страница 27: ...7 Recalling an Input Output Configuration To recall an input output configuration do the following 1 Press the RCL button The RCL button flashes 2 Press the appropriate IN or OUT SELECT button the but...

Страница 28: ...ion or choose a new action 6 2 Using Serial Commands To operate the VS 88FO using serial commands Kramer provides free control software that you can download from the Kramer Electronics Web site For a...

Страница 29: ...The USB port is used for connecting the VS 88FO to a PC to transfer the data 6 5 Changing the Device Parameters To change the device parameters do the following 1 Connect a PC to the VS 88FO see Secti...

Страница 30: ...UMIDITY 10 to 90 RHL non condensing POWER SOURCE Universal 100 240V AC 50 60Hz 24VA DIMENSIONS 19 x 7 x 1U W D H rack mountable WEIGHT 2 6kg 5 7lbs approx ACCESSORIES Power cord rack ears and IR remot...

Страница 31: ...rmat HEX Command Format ASCII Example Output 1 to Input 1 0x01 0x81 0x81 0x81 Example Output 1 to Input 1 VID1 1 CR Switching Protocol P2000 P3000 P3000 P2000 Command 0x38 0x80 0x83 0x81 Command P2000...

Страница 32: ...l buttons or by transmitting protocol commands To switch protocols using the front panel buttons To choose Protocol 2000 press OUT 1 and OUT 2 at the same time To choose the Protocol 3000 press OUT 1...

Страница 33: ...rameter_1 Parameter_2 CR 9 2 3 Command String Formal syntax with commands concatenation and addressing Start Address Body Delimiter Destination_id Command_1 Parameter1_1 Parameter1_2 Command_2 Paramet...

Страница 34: ...message closing character Note A string can contain more than one command Commands are separated by a pipe character Message starting character For host command query For machine response Device addr...

Страница 35: ...t name syntax in addition to long name syntax to allow faster typing The response is always in long syntax 9 2 9 Command Chaining Multiple commands can be chained in the same string Each command is de...

Страница 36: ...er Description IN Input number or 0 to disconnect output Connection character between in and out parameters OUT Output number or for all outputs Examples Switch video input 2 to output 4 V 2 4CR VID 2...

Страница 37: ...KCRLF Recall video connections from preset 3 PRCL 3CR PRST RCL 3 OKCRLF Show source of video output 2 from preset 3 PRST VID 3 2CR PRST VID 3 4 2 CRLF 9 3 1 Operation Commands Command Syntax Response...

Страница 38: ...CTORY_NAME RESULT Note The machine name is not the same as the model name The machine name is used to identify a specific machine or a network in use with DNS feature on MACHINE_NAME Up to 14 alphamer...

Страница 39: ...lable use IP as above Change protocol Ethernet port ETH PORT PROTOCOL PORT Short form ETHP ETH PORT PROTOCOL PORT RESULT Read protocol Ethernet port ETH PORT PROTOCOL Short form ETHP ETH PORT PROTOCOL...

Страница 40: ...10 10 10 18 18 10 10 18 18 10 10 18 18 10 10 18 18 10 10 18 18 10 10 18 18 10 10 18 11 10 IN 4 10 18 10 10 10 18 18 10 10 18 18 10 10 18 18 10 10 18 18 10 10 18 18 10 10 18 18 10 10 18 11 10 IN 5 10 1...

Страница 41: ...ng i e instruction codes 1 and 2 the INPUT 7 bits is set as the input number which is to be switched Similarly if switching is done using the machine s front panel then these bits are set with the INP...

Страница 42: ...sent to the switchers it will reset according to the present power down settings NOTE 2 These are bi directional definitions That is if the switcher receives the code it will perform the instruction a...

Страница 43: ...he OUTPUT is set as 1 then the ASCII coding of the lettering following the machine s name is sent For example for the VS 7588YC the reply to the request to send the first suffix would be HEX codes 7D...

Страница 44: ......

Страница 45: ...anual may be found We welcome your questions comments and feedback Web site www kramerelectronics com E mail info kramerel com Laser Compliance LASER PRODUCT Laser Class I acc 21 CFR 1040 and Class 1...

Отзывы: