background image

 

VS-801USB - Introduction 

 

Introduction 

Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been 
providing a world of unique, creative, and affordable solutions to the vast range of 
problems that confront video, audio, presentation, and broadcasting professionals 
on a daily basis. In recent years, we have redesigned and upgraded most of our 
line, making the best even better!  

Our 1,000-plus different models now appear in 11 groups that are clearly defined 
by function: GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Routers; 
GROUP 3: Control Systems; GROUP 4: Format/Standards Converters; GROUP 
5: Range Extenders and Repeaters; GROUP 6: Specialty AV Products; GROUP 
7: Scan Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9: 
Room Connectivity; GROUP 10: Accessories and Rack Adapters and GROUP 11: 
Sierra Video Products. 

Congratulations on purchasing your Kramer 

VS-801USB

 8x1 USB Switcher, 

which is ideal for educational institutions, presentation and display systems and 
home theater applications. 

 

 

Содержание VS-801USB

Страница 1: ...KRAMER ELECTRONICS LTD USER MANUAL MODEL VS 801USB 8x1 USB Switcher P N 2900 300030 Rev 2...

Страница 2: ......

Страница 3: ...s 10 5 2 The REMOTE Terminal Block Connector 10 5 3 The Application Software 10 6 Firmware Upgrade 11 7 Technical Specifications 12 8 Default Communication Parameters 13 9 Kramer Protocol 2000 14 10 P...

Страница 4: ...nt models now appear in 11 groups that are clearly defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Routers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5...

Страница 5: ...st performance Use only good quality connection cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables Avo...

Страница 6: ...ion 2 0 Eight DEVICE SELECT buttons Firmware upgrade via RS 232 Remote control via the RS 232 port the RC IR3 IR remote control transmitter the Ethernet and or remote contact closure An external 5V DC...

Страница 7: ...8 3 REMOTE Switch Terminal Block Connect to contact closure switches for duplicating the function of the front panel DEVICE SELECT buttons see Section 5 2 4 ETHERNET RJ 45 Connector Connect to a remo...

Страница 8: ...r Connects to a PC for firmware upgrade and control 10 PROG Push in for Program using a small screwdriver to upgrade to the latest Kramer firmware via RS 232 or release for Normal the factory default...

Страница 9: ...e hard drives and or memory sticks to the DEVICE ports For example a Hard drive to port 1 Memory stick to port 4 Hard drive to port 6 Memory stick to port 8 2 Connect the HOST USB port to an acceptor...

Страница 10: ...he RS 232 9 pin D sub front panel port on the VS 801USB unit via a 9 wire straight cable only pin 2 to pin 2 pin 3 to pin 3 and pin 5 to pin 5 need to be connected to the RS 232 9 pin D sub port on yo...

Страница 11: ...y configured default IP address After connecting the Ethernet port configure your PC as follows 1 Right click the My Network Places icon on your desktop 2 Select Properties 3 Right click Local Area Co...

Страница 12: ...ol TCP IP Properties Window 4 2 2 Connecting the ETHERNET Port via a Network Hub Straight Through Cable You can connect the Ethernet port of the VS 801USB to the Ethernet port on a network hub or netw...

Страница 13: ...ar way to the INPUT SELECT button Using the contact closure remote control also known as push to make momentary contact you can select the desired USB port To do so momentarily connect the required DE...

Страница 14: ...u can upgrade the VS 801USB via the Kramer K UPLOAD software i The latest version of K UPLOAD and installation instructions as well as the application software and its user guide can be downloaded fro...

Страница 15: ...ATURE 0 to 55 C 32 to 131 F STORAGE TEMPERATURE 45 to 72 C 49 to 162 F HUMIDITY 10 to 90 RHL non condensing DIMENSIONS 18 8cm x 11 4cm x 2 4cm 7 4 x 4 5 x 0 9 W D H WEIGHT 0 75kg 1 7lbs approx ACCESSO...

Страница 16: ...ommand P2000 CR Front Panel Press and hold DEVICE SELECT buttons 1 and 3 simultaneously Front Panel Press and hold DEVICE SELECT buttons 1 and 2 simultaneously Ethernet IP Address 192 168 1 39 Subnet...

Страница 17: ...switching ie instruction codes 1 and 2 the INPUT 7 bits is set as the input number which is to be switched Similarly if switching is done via the machine s front panel then these bits are set with th...

Страница 18: ...nd the OUTPUT is assigned the value of the requested parameter The replies to instructions 10 and 11 are as per the definitions in instructions 7 and 8 respectively For example if the present status o...

Страница 19: ...ing with only one command without addressing Start Body Delimiter Command SP Parameter_1 Parameter_2 CR 10 1 1 2 Command String Formal syntax with commands concatenation and addressing Start Address B...

Страница 20: ...message closing character Note A string can contain more than one command Commands are separated by a pipe character Message starting character For host command query For device response Device addre...

Страница 21: ...as X Refer to the controller manual 10 1 5 Command Forms Some commands have short name syntax in addition to long name syntax to allow faster typing The response is always in long syntax 10 1 6 Chaini...

Страница 22: ...E RST Reset machine DNS name to factory default Administrator NET DHCP NTDH Set DHCP mode Administrator NET DHCP NTDH Get DHCP mode End User NET GATE NTGT Set Gateway IP Administrator NET GATE NTGT Ge...

Страница 23: ...20 VS 801USB Protocol 3000...

Страница 24: ...sit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site www kramerelectronics com E mail info kramerel com P N 2900 300030 Rev 2 SAFETY...

Отзывы: