Kramer Protocol 2000 

 

 

24 

NOTE  6

  –  If  INPUT  is  set  to  127  for  these  instructions,  then,  if  the  function  is  defined  on  this  machine,  it  replies  with 

OUTPUT=1. If the function is not defined, then the machine replies with OUTPUT=0, or with an error (invalid instruction 

code).  

 

If the INPUT is set to 126 for these instructions, then, if possible, the machine will return the current setting of this function, 

even for the case that the function is not defined. For example, for a video switcher which always switches during the VIS of 

input #1, (and its VIS setting cannot be programmed otherwise), the reply to the HEX code 

0A 

FE 

80 

81 (i.e. request VIS setting, with INPUT set as 126dec)  

would be HEX codes 

4A 

FE 

81 

81 (i.e. VIS setting = 1, which is defined as VIS from input #1). 

 

NOTE 7

 – Setting OUTPUT to 0 will return the VIS source setting as defined in instruction #7. Setting to 1 will return the 

input # or output # of the sync source (for the case where the VIS source is set as 6 or as 7 in instruction #7). Setting to 2 

returns the vertical sync frequency (0 for no input sync, 50 for PAL, 60 for NTSC, 127 for error).  

 

NOTE  8

  -  The  reply  to  the  "REQUEST  WHETHER  SETUP  IS  DEFINED"  is  as  in  TYPE  3  above,  except  that  here  the 

OUTPUT is assigned with the value 0 if the setup is not defined; or 1 if it is defined. 

 

NOTE  9

  -  An  error  code  is  returned  to  the  PC  if  an  invalid  instruction  code  was  sent  to  the  switcher,  or  if  a  parameter 

associated with the instruction is out of range (e.g. trying to save to a setup greater than the highest one, or trying to switch an 

input or output greater than the highest one defined). This code is also returned to the PC if an RS-232 instruction is sent while 

the machine is being programmed via the front panel. Reception of this code by the switcher is not valid. 

 

NOTE 10

 – This code is reserved for internal use. 

 

NOTE 11

 – For machines where the video and / or audio gain is programmable. 

 

NOTE 12

 - Under normal conditions, the machine's present status is saved each time a change is made. The "power-down" 

save (auto-save) may be disabled using this code. Note that whenever the machine is turned on, the auto-save function is set. 

 

NOTE 13

 - This is a request to identify the switcher/s in the system. If the OUTPUT is set as 0, and the INPUT is set as 1, 2, 5 

or 7, the machine will send its name. The reply is the decimal value of the INPUT and OUTPUT. For example, for a 2216, the 

reply to the request to send the audio machine name would be (HEX codes): 

 

7D 

96 

90 

81  (i.e.  22dec for 2nd byte, and  16dec for 3rd byte). 

 

If the request for identification is sent with the INPUT set as 3 or 4, the appropriate machine will send its software version 

number. Again, the reply would be the decimal value of the INPUT and OUTPUT - the INPUT representing the number in 

front of the decimal point, and the OUTPUT representing the number after it. For example, for version 3.5, the reply to the 

request to send the version number would be (HEX codes): 

 

7D 

83 

85 

81  (i.e.  3dec for 2nd byte,  5dec for 3rd byte). 

 

If the OUTPUT is set as 1, then the ASCII coding of the lettering following the machine’s name is sent. For example, for the 

VS-7588YC, the reply to the request to send the first suffix would be (HEX codes): 

 

7D 

D9 

C3 

81  (i.e.  ASCII for “ Y” ;  ASCII for “ C” ). 

 

NOTE 14

 - The number of inputs and outputs refers to the specific machine, which is being addressed, not to the system. For 

example, if six 16X16 matrices are configured to make a 48X32 system (48 inputs, 32 outputs), the reply to the HEX code 

3E 

82 

81 

82 (ie. request the number of outputs)  

would be HEX codes 

7E 

82 

90 

82 

i.e. 16 outputs 

 

NOTE 15

 – When the OVR bit (4th byte) is set, then the “ video”  commands have universal meaning. For example, instruction 

1  (SWITCH  VIDEO)  will  cause  all  units  (including  audio,  data,  etc.)  to  switch.  Similarly,  if  a  machine  is  in  “ FOLLOW”  

mode, it will perform any “ video”  instruction. 

  

NOTE 16

 - The reply to the “ REQUEST WHETHER PANEL IS LOCKED”  is as in NOTE 4 above, except that here the 

OUTPUT is assigned with the value 0 if the panel is unlocked, or 1 if it is locked. 

 

NOTE 17

 – Delayed execution allows switching after a delay dictated by RS-232. To do this, the user sends instruction 7 with 

the “ Set for delayed switch”  option (64dec) before sending the switch command (instruction 1) or pressing via front panel. The 

switch is not executed (unless timed-out) until the “ Execute delayed switch”  code is sent, or the “ “ Set for delayed switch”  

code  is  sent  again.  (The  mode  is  automatically  cancelled  after  implementation  of  the  switch  if  the  “ execute”   command  is 

used). 

For example, to connect input 4 to output 3 after a delay, send HEX codes 

07 

80 

C0 

81  

(set for delayed switch) 

01 

84 

83 

81  

(switch code) 

Содержание VS-66FW

Страница 1: ...Kramer Electronics Ltd USER MANUAL Model VS 66FW 6 Port FireWire Switcher...

Страница 2: ...etting the MACHINE 11 5 5 Connecting the REMOTE Connector 11 6 Operating the VS 66FW 12 6 1 Displaying Unit Characteristics 12 6 2 Switching LEAF BRANCH Combinations 13 6 3 Confirming Settings 13 6 3...

Страница 3: ...Figure 10 Splash Screen 17 Figure 11 Atmel Flip Window 17 Figure 12 Open Configuration File Select Window 18 Figure 13 Atmel Flip Window RS 232 Communication 18 Figure 14 RS 232 Window 19 Figure 15 A...

Страница 4: ...on 4 the REMOTE connector PINOUT is altered The seventh PIN leaf is now labeled LF and the eighth PIN branch is now labeled BR Page 11 Figure 7 in section 5 5 the REMOTE connector PINOUT is replaced F...

Страница 5: ...that you Unpack the equipment carefully and save the original box and packaging materials for possible future shipment Review the contents of this user manual Use Kramer high performance high resoluti...

Страница 6: ...with FireWire and i LINK implementation of IEEE Std 1394 Is fully compliant with OpenHCI requirements Provides P1394a Fully Compliant Cable Ports at 100 200 400 Megabits per Second Mbits s Includes fu...

Страница 7: ...ng with the front panel Is housed in a 19 1U rack mountable enclosure You can control the VS 66FW via the Front panel buttons Infra red remote control transmitter Remote contact closure switches Remot...

Страница 8: ...ol switcher the front panel has separate Branch and Leaf buttons but the rear panel has shared Branch Leaf connectors FireWire ports 3 3 3 Configuring as a FireWire Hub The VS 66FW is a 6 Port FireWir...

Страница 9: ...be configured1 as a 6 port FireWire hub in which the bi directional signals flow between Port 4 and all the other ports Figure 2 Configuring the VS 66FW as a 6 Port FireWire Hub 4 Defining the VS 66F...

Страница 10: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Defining the VS 66FW 6 Port FireWire Switcher 6 Figure 3 VS 66FW 6 Port FireWire Switcher...

Страница 11: ...int between each LEAF to which the BRANCH displayed below it is connected 12 BRANCH 7 segment Display5 shows the selected BRANCH switched to the LEAF under the corresponding LEAF label 13 PORT STATUS...

Страница 12: ...camcorder to a computer and from another video camcorder to a laptop The data from the computer is stored on an external hard drive To connect the VS 66FW as the example in Figure 4 illustrates do th...

Страница 13: ...r panel port on the VS 66FW unit to the Null modem adapter and connect the Null modem adapter with a 9 wire flat cable to the RS 232 DB9 port on your PC To connect a PC to the VS 66FW unit without usi...

Страница 14: ...N on one of the units for example on the RS 485 remote controller 2 Set the SETUP dipswitches on the VS 66FW unit as follows Set the first VS 66FW unit to MACHINE 11 Set the second VS 66FW unit to MAC...

Страница 15: ...Dipswitch Settings DIPSWITCH DIPSWITCH MACHINE 1 2 3 4 MACHINE 1 2 3 4 1 ON OFF OFF OFF 9 ON OFF OFF ON 2 OFF ON OFF OFF 10 OFF ON OFF ON 3 ON ON OFF OFF 11 ON ON OFF ON 4 OFF OFF ON OFF 12 OFF OFF O...

Страница 16: ...RS 485 serial commands transmitted by a touch screen system PC or other serial controller 6 1 Displaying Unit Characteristics Switching on the VS 66FW unit momentarily displays the following test1 in...

Страница 17: ...1 describes When the VS 66FW operates in the AT ONCE mode pressing a LEAF BRANCH combination implements the switch immediately In the CONFIRM mode the TAKE button must be pressed to authorize the swi...

Страница 18: ...onfirming a Switching Action To confirm a switching action in CONFIRM mode do the following LEAF BRANCH 1 Press a LEAF BRANCH combination The corresponding digits in the 7 segment Display blink The TA...

Страница 19: ...er pressing the TAKE button The memory recalls the stored data from that reference Tip If you cannot remember which of the 6 configurations is the one that you want set the VS 66FW to the CONFIRM mode...

Страница 20: ...o the RS 232 Port Before installing the latest Kramer firmware version on a VS 66FW unit do the following 1 Connect the RS 232 DB9 rear panel port on the VS 66FW unit to the Null modem adapter and con...

Страница 21: ...seconds the Splash screen is replaced by the Atmel Flip window Figure 11 Atmel Flip Window 3 Press the keyboard shortcut key F4 or select the Read Configuration File command from the File menu or pre...

Страница 22: ...selected an RS 232 error message appears In the Atmel Flip window the Operations Flow column is disabled and crosses appear in the third column Figure 13 Atmel Flip Window RS 232 Communication 5 Click...

Страница 23: ...Information column the HEX File VS_66FW_12 hex appears Figure 15 Atmel Flip Window Connected 7 Click Run After each stage in the operation is completed the check box for that stage becomes colored gre...

Страница 24: ...the POWER switch on the VS 66FW OFF 10 Disconnect the RS 232 DB9 rear panel port on the VS 66FW unit from the Null modem adapter 11 On the rear panel release the FLASH button1 to Normal using a screw...

Страница 25: ...M and RS 485 on a detachable terminal block remote dry contacts on a terminal block POWER SOURCE 100 240 VAC 50 60 Hz 90VA DIMENSIONS 19 inch W 7 inch D 1U H rack mountable WEIGHT 2 2 kg 4 9 lbs appr...

Страница 26: ...INSTRUCTION NO is the value to be set for N5 N0 2nd BYTE Bit 7 Defined as 1 I6 I0 INPUT When switching ie instruction codes 1 and 2 the INPUT 7 bits is set as the input number which is to be switched...

Страница 27: ...r down settings NOTE 2 These are bi directional definitions That is if the switcher receives the code it will perform the instruction and if the instruction is performed due to a keystroke operation o...

Страница 28: ...set as 0 and the INPUT is set as 1 2 5 or 7 the machine will send its name The reply is the decimal value of the INPUT and OUTPUT For example for a 2216 the reply to the request to send the audio mac...

Страница 29: ...o 10013dec 271Dhex first send HEX codes 3F 80 CE 81 followed by HEX codes 16 86 9D 81 NOTE 20 To store data in the non volatile memory of the unit e g the EEPROM for saving SETUPS The EEPROM address i...

Страница 30: ...is required the original dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a contact name...

Страница 31: ...m P N 2900 000066 REV 1 For the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com Updates to this user manual may be found at http www k...

Отзывы: