Kramer VS-66FW Скачать руководство пользователя страница 27

Kramer Protocol 2000 

 

23

For  a  single  machine  controlled  via  the  serial  port,  always  set  M4…M0  =  1,  and  make  sure  that  the  machine  itself  is 

configured as MACHINE NUMBER = 1.  

Table 8: Instruction Codes for Protocol 2000 (Relevant to the VS-66FW) 

Note: All values in the table are decimal, unless otherwise stated. 

 

INSTRUCTION 

DEFINITION FOR SPECIFIC INSTRUCTION 

DESCRIPTION 

INPUT 

OUTPUT 

NOTE 

0, 18 

RESET 

SWITCH VIDEO 

Set equal to video input which is 

to be switched 

(0 = disconnect) 

Set equal to video output which is to be 

switched 

(0 = to all the outputs) 

2, 15 

STORE VIDEO and 

AUDIO STATUS 

Set as SETUP # 

0 - to store 

1 - to delete 

2, 3, 15 

RECALL VIDEO 

STATUS 

Set as SETUP # 

2, 3, 15 

REQUEST STATUS 

OF A VIDEO OUTPUT 

Set as SETUP # 

Equal to output number whose status is reqd  4, 3 

15 

REQUEST WHETHER 

SETUP IS DEFINED 

Set as SETUP # 

16 

ERROR / BUSY 

0 - error 

1 - invalid instruction 

2 - out of range 

30 

LOCK FRONT PANEL 

0 - Panel unlocked 

1 - Panel locked 

31 

REQUEST WHETHER 

PANEL IS LOCKED 

16 

61 

IDENTIFY MACHINE   1 - video machine name 

2 - audio machine name 

3 - video software version 

4 - audio software version 

0 - Request first 4 digits 

13 

62 

DEFINE MACHINE  

1 - number of inputs 

2 - number of outputs 

3 - number of setups 

1 - for video 

2 - for audio 

14 

NOTES on the above table: 

 

NOTE 1

 - When the master switcher is reset, (e.g. when it is turned on), the reset code is sent to the PC. If this code is sent to 

the switchers, it will reset according to the present power-down settings. 

 

NOTE 2

 - These are bi-directional definitions. That is, if the switcher receives the code, it will perform the instruction; and if 

the instruction is performed (due to a keystroke operation on the front panel), then these codes are sent. For example, if the 

HEX code 

01  

85 

88  

83 

was sent from the PC, then the switcher (machine 3) will switch input 5 to output 8. If the user switched input 1 to output 7 via 

the front panel keypad, then the switcher will send HEX codes: 

41 

81 

87 

83 

to the PC. 

When the PC sends one of the commands in this group to the switcher, then, if the instruction is valid, the switcher replies by 

sending to the PC the same four bytes that it was sent (except for the first byte, where the DESTINATION bit is set high).   

 

NOTE 3

 - SETUP # 0 is the present setting. SETUP # 1 and higher are the settings saved in the switcher's memory, (i.e. those 

used for Store and Recall). 

 

NOTE  4

  -  The  reply  to  a  "REQUEST"  instruction  is  as  follows:  the  same  instruction  and  INPUT  codes  as  were  sent  are 

returned, and the OUTPUT is assigned the value of the requested parameter. The replies to instructions 10 and 11 are as per 

the  definitions  in  instructions  7  and  8  respectively.  For  example,  if  the  present  status  of  machine  number  5  is  breakaway 

setting, then the reply to the HEX code 

0B 

80 

80 

85 

would be HEX codes 

4B 

80 

81 

85 

 

NOTE 5

 – For the OUTPUT byte set as 6, the VIS source is the input selected using the OUTPUT byte. Similarly, for the 

OUTPUT byte set as 7, the VIS source is the output selected using the OUTPUT byte. Note also, that on some machines the 

sync source is not software selectable, but is selected using switches, jumpers, etc!  

 

Содержание VS-66FW

Страница 1: ...Kramer Electronics Ltd USER MANUAL Model VS 66FW 6 Port FireWire Switcher...

Страница 2: ...etting the MACHINE 11 5 5 Connecting the REMOTE Connector 11 6 Operating the VS 66FW 12 6 1 Displaying Unit Characteristics 12 6 2 Switching LEAF BRANCH Combinations 13 6 3 Confirming Settings 13 6 3...

Страница 3: ...Figure 10 Splash Screen 17 Figure 11 Atmel Flip Window 17 Figure 12 Open Configuration File Select Window 18 Figure 13 Atmel Flip Window RS 232 Communication 18 Figure 14 RS 232 Window 19 Figure 15 A...

Страница 4: ...on 4 the REMOTE connector PINOUT is altered The seventh PIN leaf is now labeled LF and the eighth PIN branch is now labeled BR Page 11 Figure 7 in section 5 5 the REMOTE connector PINOUT is replaced F...

Страница 5: ...that you Unpack the equipment carefully and save the original box and packaging materials for possible future shipment Review the contents of this user manual Use Kramer high performance high resoluti...

Страница 6: ...with FireWire and i LINK implementation of IEEE Std 1394 Is fully compliant with OpenHCI requirements Provides P1394a Fully Compliant Cable Ports at 100 200 400 Megabits per Second Mbits s Includes fu...

Страница 7: ...ng with the front panel Is housed in a 19 1U rack mountable enclosure You can control the VS 66FW via the Front panel buttons Infra red remote control transmitter Remote contact closure switches Remot...

Страница 8: ...ol switcher the front panel has separate Branch and Leaf buttons but the rear panel has shared Branch Leaf connectors FireWire ports 3 3 3 Configuring as a FireWire Hub The VS 66FW is a 6 Port FireWir...

Страница 9: ...be configured1 as a 6 port FireWire hub in which the bi directional signals flow between Port 4 and all the other ports Figure 2 Configuring the VS 66FW as a 6 Port FireWire Hub 4 Defining the VS 66F...

Страница 10: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Defining the VS 66FW 6 Port FireWire Switcher 6 Figure 3 VS 66FW 6 Port FireWire Switcher...

Страница 11: ...int between each LEAF to which the BRANCH displayed below it is connected 12 BRANCH 7 segment Display5 shows the selected BRANCH switched to the LEAF under the corresponding LEAF label 13 PORT STATUS...

Страница 12: ...camcorder to a computer and from another video camcorder to a laptop The data from the computer is stored on an external hard drive To connect the VS 66FW as the example in Figure 4 illustrates do th...

Страница 13: ...r panel port on the VS 66FW unit to the Null modem adapter and connect the Null modem adapter with a 9 wire flat cable to the RS 232 DB9 port on your PC To connect a PC to the VS 66FW unit without usi...

Страница 14: ...N on one of the units for example on the RS 485 remote controller 2 Set the SETUP dipswitches on the VS 66FW unit as follows Set the first VS 66FW unit to MACHINE 11 Set the second VS 66FW unit to MAC...

Страница 15: ...Dipswitch Settings DIPSWITCH DIPSWITCH MACHINE 1 2 3 4 MACHINE 1 2 3 4 1 ON OFF OFF OFF 9 ON OFF OFF ON 2 OFF ON OFF OFF 10 OFF ON OFF ON 3 ON ON OFF OFF 11 ON ON OFF ON 4 OFF OFF ON OFF 12 OFF OFF O...

Страница 16: ...RS 485 serial commands transmitted by a touch screen system PC or other serial controller 6 1 Displaying Unit Characteristics Switching on the VS 66FW unit momentarily displays the following test1 in...

Страница 17: ...1 describes When the VS 66FW operates in the AT ONCE mode pressing a LEAF BRANCH combination implements the switch immediately In the CONFIRM mode the TAKE button must be pressed to authorize the swi...

Страница 18: ...onfirming a Switching Action To confirm a switching action in CONFIRM mode do the following LEAF BRANCH 1 Press a LEAF BRANCH combination The corresponding digits in the 7 segment Display blink The TA...

Страница 19: ...er pressing the TAKE button The memory recalls the stored data from that reference Tip If you cannot remember which of the 6 configurations is the one that you want set the VS 66FW to the CONFIRM mode...

Страница 20: ...o the RS 232 Port Before installing the latest Kramer firmware version on a VS 66FW unit do the following 1 Connect the RS 232 DB9 rear panel port on the VS 66FW unit to the Null modem adapter and con...

Страница 21: ...seconds the Splash screen is replaced by the Atmel Flip window Figure 11 Atmel Flip Window 3 Press the keyboard shortcut key F4 or select the Read Configuration File command from the File menu or pre...

Страница 22: ...selected an RS 232 error message appears In the Atmel Flip window the Operations Flow column is disabled and crosses appear in the third column Figure 13 Atmel Flip Window RS 232 Communication 5 Click...

Страница 23: ...Information column the HEX File VS_66FW_12 hex appears Figure 15 Atmel Flip Window Connected 7 Click Run After each stage in the operation is completed the check box for that stage becomes colored gre...

Страница 24: ...the POWER switch on the VS 66FW OFF 10 Disconnect the RS 232 DB9 rear panel port on the VS 66FW unit from the Null modem adapter 11 On the rear panel release the FLASH button1 to Normal using a screw...

Страница 25: ...M and RS 485 on a detachable terminal block remote dry contacts on a terminal block POWER SOURCE 100 240 VAC 50 60 Hz 90VA DIMENSIONS 19 inch W 7 inch D 1U H rack mountable WEIGHT 2 2 kg 4 9 lbs appr...

Страница 26: ...INSTRUCTION NO is the value to be set for N5 N0 2nd BYTE Bit 7 Defined as 1 I6 I0 INPUT When switching ie instruction codes 1 and 2 the INPUT 7 bits is set as the input number which is to be switched...

Страница 27: ...r down settings NOTE 2 These are bi directional definitions That is if the switcher receives the code it will perform the instruction and if the instruction is performed due to a keystroke operation o...

Страница 28: ...set as 0 and the INPUT is set as 1 2 5 or 7 the machine will send its name The reply is the decimal value of the INPUT and OUTPUT For example for a 2216 the reply to the request to send the audio mac...

Страница 29: ...o 10013dec 271Dhex first send HEX codes 3F 80 CE 81 followed by HEX codes 16 86 9D 81 NOTE 20 To store data in the non volatile memory of the unit e g the EEPROM for saving SETUPS The EEPROM address i...

Страница 30: ...is required the original dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a contact name...

Страница 31: ...m P N 2900 000066 REV 1 For the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com Updates to this user manual may be found at http www k...

Отзывы: