MENU Commands Sequence
KRAMER ELECTRONICS, LTD.
42
Plan your system according to the chart in Figure 8 before setting the
MACHINE ADDRESS, because in a matrix configuration you need to enter
the highest MACHINE ADDRESS as well as the MACHINE ADDRESS.
8.4.1
Changing the MACHINE ADDRESS from stand alone to a large matrix
To set the MACHINE ADDRESS:
1. Press the MENU button until you reach the MACHINE ADDRESS
command.
The MATRIX Display shows the message:
MACHINE ADDRESS
setting yes -> TAKE, next -> MENU
2. Press the
TAKE
button.
The Displays show the messages:
OUTkey 1: Stand-Alone UNIT
2: Large Matrix
Current
Alone
1
3. Press the
OUT
button
#
2
.
The TAKE LED blinks and the Displays show the messages:
Change to the LARGE MATRIX?
Press TAKE to confirm
Current
16x16
2
4. Press the
TAKE
button again.
The Displays show the messages:
READY to set MACHINE ADDRESS
use OUTkey 1-9, 0
Current #
1
5. Enter the MACHINE ADDRESS by pressing an
OUT
button
#
1-9, 0
.
The STATUS Display shows the message:
current:
x
Where x is the OUT button # pressed
6. Press the
TAKE
button again.
The Displays show the messages:
READY to change MACH. ADDR.
Press TAKE to confirm
From # 01
to # x
1 Indicating that the machine is not set to the large matrix setting
2 For example, if currently configured for stand alone