Installing the Video Matrix Switcher
KRAMER ELECTRONICS, LTD.
10
inputs and 16 outputs. However, for s-Video (Y/C) configuration you need 2
VS-1616V
units to provide 16 inputs and 16 outputs.
In a multi-channel video switcher configuration, only one unit is the Master
(with DIP 6 OFF). The other units are Slaves (with DIP 6 ON).
The front panel of each Slave unit is always locked and the
MATRIX
and
STATUS
LCD Displays do not illuminate. The Slave units follow the Master.
The Master unit operates in the regular way
1
, leading the Slaves in the
background.
To activate a multi-channel video switcher so that each unit is in the same
state from the outset, do not turn on the power on the Slave units after the
Master unit.
Table 5: Multi-channel VS-1616V Configuration for CV, Y/C, YUV (RGB) and RGBS
Configuration Number of VS-1616V Units required
to make up a 16x16 Switcher
Composite
1
s-Video (Y/C)
2
YUV / RGB
3
RGBS
4
6.2.1
Configuring a 16x16 Y/C Switcher (2 Units)
Configure a 16x16 video matrix switcher for s-Video (Y/C) by combining 2
VS-1616V
switchers. Connect as in Figure 7, substituting the C unit for the U
unit and ignoring the V unit. Set the dipswitches as Figure 7 illustrates.
Connect the communication line via the RS-232
or
RS-485 control interface
as section 6.6 describes.
6.2.2
Configuring a 16x16 YUV/RGB Switcher (3 Units)
Configure a 16x16 video matrix switcher for YUV by combining
2
3
VS-1616V
switchers, as Figure 7 illustrates:
1 The front panel is not locked and the MATRIX and STATUS LCD Displays illuminate
2 For a description of how to connect the RS-485 connectors between the VS-1616V switchers, refer to section 6.6.2