Kramer Electronics Ltd.
VS-1616DN-EM
– Protocol 3000
134
LDEDID
Functions
Permission
Transparency
Set
LDEDID
End User
Public
Get
-
-
-
Description
Syntax
Set
Write EDID data from external application
to device
Multi-step syntax (see following steps)
Get
-
-
Response
Step 1:
#
LDEDID
SP
eeprom_ID,size
CR
Response 1:
~nn@
LDEDID
SP
eeprom_id,size
SP
READY
CR LF
or
~nn@
LDEDID
SP
ERRnn
CR LF
Step 2: If
READY
was received, send
EDID_DATA
Response 2:
~nn@
LDEDID
SP
eeprom_id,size
SP
OK
CR LF
Parameters
eeprom_id
–
Input port
EEPROM destination for the EDID data:
1-16
(varies according to installed input
size
–
EDID data size
EDID_DATA
– HEX or KFW file in protocol packets (see
Response Trigger
Response is sent to the com port from which the Set (before execution) command was received
Notes
When the unit receives the
LDEDID
command it replies with
READY
and enters the special EDID packet
wait mode. In this mode the unit can receive only packets and not regular protocol commands.
If the unit does not receive correct packets for 30 seconds or is interrupted for more than 30 seconds
before receiving all packets, it sends timeout error
~nn@
LDEDID
SP
ERR01
CR LF
and returns to the
regular protocol mode. If the unit received data that is not a correct packet, it sends the corresponding
error and returns to the regular protocol mode.
K-Config Example
Write EDID data from external application to Input 1:
“#LDEDID 1,256”,0x0D
LOCK-FP
Functions
Permission
Transparency
Set
LOCK-FP
End User
Public
Get
LOCK-FP?
End User
Public
Description
Syntax
Set
Lock front panel
#
LOCK-FP
SP
lock_mode
CR
Get
Get front panel lock state
#
LOCK-FP?
CR
Response
Set:
~nn@
LOCK-FP
SP
lock_mode
SP
OK
CR LF
Get:
~nn@
LOCK-FP
SP
lock_mode
CR LF
Parameters
lock_mode
–
0/OFF
(unlocks the front panel buttons),
1/ON
(locks the front panel buttons)
Response Trigger
Notes
K-Config Example
Lock the front panel of the
VS-1616DN-EM
:
“#LOCK
-
FP 1”,0x0D