Default Communication Parameters
37
37
12 Default Communication Parameters
Table 11
lists the default communication parameters for the
VP-81SID
.
Table 11: Communication Parameters
RS-232
Protocol 3000
Baud Rate:
115200
Data Bits:
8
Stop Bits:
1
Parity:
None
Command Format:
ASCII
Example (Output 2 to Input 4):
#AV 4>2<CR>
Factory Default Ethernet Values
To reset the IP settings to the factory reset values, power cycle the device while holding in the
Factory Reset button, located on the rear panel of the unit
IP Address:
192.168.1.39
Subnet mask:
255.255.255.0
Default gateway:
192.168.1.1
TCP Port #: 5000
5000
UDP Port #: 50000
50000
Maximum UDP Ports:
10
Maximum TCP Ports:
4
13 Default EDID
Each input on the
VP-81SID
is loaded with an EDID detected on output. If no
output EDID is detected, factory default will be used.
Monitor
Model name............... VP-81SID
Manufacturer Name = KRM
Product Code = 4608
Serial Number = 16843009
Week of Manufacture = 255
Year of Manufacture = 2011
EDID Version = 1.3
--- Video Input Definition ---
Signal Type = Digital
DFP 1.x = Not Compatible
--- Basic Display Parameters ---
Max Horizontal Size(cm) = 52
Max Vertical Size(cm) = 32
Gamma Value = 2.20
--- Display Features ---
Standby Mode = Supported
Suspend Mode = Supported
Active Off Mode = Supported
Display Type = RGB
Color Space = Alternate
Preferred Timing = 1st Detail
GTF Timing = Not Supported
--- Color Characteristics ---
Red x = 0.674
Red y = 0.318
im Vertrieb von CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201