KRAMER: SIMPLE CREATIVE TECHNOLOGY
Configuring the VP-730 via the OSD MENU Screens
34
Setting
Function
Selection/Range
Default
Save Lock
Set the Save Lock option to ON to save the
lock status when the machine is powered
down
On/Off
Off
Input Lock
Set the Input Lock to OFF so you can still use
the SOURCE buttons on the front panel even
when the lock button is on
On/Off
On
Firmware
Download
Download the firmware via the USB
connection
Confirmation
Logo Download
Download a new logo via the USB connection
Blank
Define the function of the BLANK front panel
button
Blank & Mute, Blank,
Mute
Blank &
Mute
Freeze
Define the function of the FREEZE front
panel button
Freeze & Mute, Freeze,
Mute
Freeze &
Mute
HDCP Setting
Define whether the HDCP will follow the input
or the output
Follow Input
1
, Follow
Output
2
Monitor
Overscan
Allows stretching of the outputted
On, Off
Off
Table 16: Input Functions
Setting
Function
Range
Default
Custom Input
Custom Input
Custom 1 to custom 4
Custom 1
HT
Horizontal Total
1344
HW
Horizontal sync pulse width
136
HS
Horizontal active start point
296
HA
Horizontal active region
1024
HP
Horizontal polarity
VT
Vertical Total
806
VW
Vertical sync pulse width
6
VS
Vertical active start point
35
VA
Vertical active region
768
VP
Vertical polarity
OCLK
Output clock
65
Enable
Set to On to enable parameter
change
Off
Save
Apply settings
N/A
1 When Follow Input is selected, the Scaler changes its HDCP output setting (for the HDMI output) according to the HDCP
of the input. This option is recommended when the HDMI Scaler output is connected to a splitter/switcher (in this mode,
switching may not be glitch-free)
2 When Follow Output is selected, the Scaler matches its HDCP output to the HDCP setting of the HDMI acceptor to which it
is connected. This ensures smooth switching, regardless of the input