48
VP-725N - VP-725N Communication Protocol
Communication Protocol of the
VP-725N
Control Type Function Parameter
Description
Set
Get
0
1
56
0: Keystone
1: Anyplace
2: Rotation
Geometry Application
0
1
57
0: Front
1: Ceiling
2: Rear
3: Rear ceiling
Geometry Location
0
1
58
-40 ~ 40
Geometry Horizontal Keystone
0
1
59
-30~30
Geometry Vertical Keystone
0
1
60
-2000~2000
Geometry Diagonal Projection - Top Left H
0
1
61
-2000~2000
Geometry Diagonal Projection - Top Left V
0
1
62
-2000~2000
Geometry Diagonal Projection - Top Right H
0
1
63
-2000~2000
Geometry Diagonal Projection - Top Right V
0
1
64
-2000~2000
Geometry Diagonal Projection - Bottom Left H
0
1
65
-2000~2000
Geometry Diagonal Projection - Bottom Left V
0
1
66
-2000~2000
Geometry Diagonal Projection - Bottom Right H
0
1
67
-2000~2000
Geometry Diagonal Projection - Bottom Right V
0
-
68
N/A
Geometry Diagonal Projection – Reset
0
1
69
-20 ~ 20
Geometry Pincushion/Barrel
0
1
70
-180 ~ 180
Geometry Rotation
0
-
71
N/A
Geometry Reset all