Kramer Electronics Ltd.
VM-10H2
– Protocol 3000
21
DISPLAY
Functions
Permission
Transparency
Set:
-
-
-
Get
DISPLAY?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get output HPD status
#DISPLAY?
SP
out_id
CR
Response
~
nn
@DISPLAY
SP
out_id
,
status
CR LF
Parameters
out_id
– output number
status
– HPD status according to signal validation
0 - Signal or sink is not valid
1 - Signal or sink is valid
2 - Sink and EDID is valid
Response Triggers
After execution, response is sent to the com port from which the Get was received
Response is sent after every change in output HPD status ON to OFF
Response is sent after every change in output HPD status OFF to ON and ALL parameters (new EDID,
etc.) are stable and valid
Notes
K-Config Example
Get the output HPD status of OUT 1:
“#DISPLAY? 1”,0x0D
DPSW-STATUS
Functions
Permission
Transparency
Set:
-
-
-
Get:
DPSW-STATUS?
End User
Public
Description
Syntax
Set:
-
-
Get :
Get the DIP-switch state
# DPSW-STATUS?
SP
dp_sw_id
CR
Response
~
nn
@DPSW-STATUS?
SP
dp_sw_id
,
status
CR LF
Parameters
dp_sw_id
– 1….num of DIP switches
status
– 0: up, 1: down
Response Triggers
Notes
K-Config Example
get the DIP-switch 2 status:
“#DPSW
-
STATUS? 2”,0x0D