Kramer Electronics Ltd.
TP-594Txr, TP-594Rxr
– Using the Embedded Web Pages
40
3. When Control Gateway Status is enabled, perform the following operations:
▪
Route RS-232 port control communication via
Gateway
or via
HDBT-Line
(default)
extension.
When routing commands via gateway, and sending replies to a new client is
enabled (see
Setting TP-594Rxr Gateway Serial Port Settings
),
RS-232 responses are sent to other gateway Clients too.
▪
Route IR port control communication via
Gateway
or
HDBT-Line
(default) extension.
▪
Route CEC port control communication either via
Gateway and HDBT-Line
(both
are active) or only via
HDBT-Line
(default)
extension (gateway CEC communication
is blocked).
When control gateway is enabled and CEC (HDMI) port control communication is via
Gateway
,
define the following CEC-enabled controI gateway attributes:
Enter the CEC logical address (14, by default) of the control gateway.
View the list of logical addresses for CEC-enabled devices connected on HDMI
line as members of the CEC control channel.
Click
CEC List Refresh
to update the logical address list of CEC members.
According to HDMI CEC standard, for proper identification during CEC control
communication, each CEC-enabled member of the CEC control channel, is assigned a CEC
logical address.
Sending Commands Manually via Gateway
Use Manual Control to manually control a peripheral device that is connected to
TP-594Rxr
,
via RS-232, IR or HDMI-CEC control ports.
Before manually controlling via RS-232 port, you need to define it as a control gateway serial
port (see
Setting TP-594Rxr Gateway Serial Port Settings
To send commands manually:
1. In the Navigation pane select
Control Gateway
. The Gateway & Ports Activation page
appears.
2. Under Manual Control, select the Control Port (RS-232, IR or CEC).
3. Enter a Hex command.
DRAFT