28
TP-588D - Protocol 3000
Command -
MODEL?
Command Type - System-mandatory
Command Name
Permission
Transparency
Set:
-
-
-
Get:
MODEL?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get device model
#
MODEL?
␍
Response
~nn@
MODEL
␠
model_name
␍␊
Parameters
model_name - String of up to 19 printable ASCII chars
Response Triggers
Notes
Command -
NAME
Command Type - System (Ethernet)
Command Name
Permission
Transparency
Set:
NAME
Administrator
Public
Get:
NAME?
End User
Public
Description
Syntax
Set:
Set machine (DNS) name
#
NAME
␠
machine_name
␍
Get:
Get machine (DNS) name
#
NAME?
␍
Response
Set: ~nn@
NAME
␠
machine_name
␍␊
Get: ~nn@
NAME?
␠
machine_name
␍␊
Parameters
machine_name
- String of up to 14 alpha-numeric chars (can include hyphen, not at the beginning or end)
Response Triggers
Notes
The machine name is not the same as the model name. The machine name is used to identify a specific
machine or a network in use (with DNS feature on)