background image

 

TP-588D - Protocol 3000

 

23 

 

23 

10.2 

Kramer Protocol 3000 Commands  

Command  

Description  

Protocol handshaking 

BUILD-DATE? 

Read device build date 

DISPLAY? 

Read if output is valid 

ETH-PORT 

Set Ethernet port protocol 

EDID-CS 

Set/get EDID color space 

FACTORY 

Reset to factory default configuration 

HDCP-MOD 

Set HDCP mode 

HDCP-STAT? 

Get HDCP signal status 

HELP 

List of commands 

MODEL? 

Read device model 

NAME 

Set machine (DNS) name 

NAME-RST 

Reset machine name to factory default (DNS) 

NET-DHCP 

Set DHCP mode 

NET-GATE 

Set gateway IP 

NET-IP 

Set IP address 

NET-MAC? 

Get MAC address 

NET-MASK 

Set subnet mask 

PROT-VER? 

Read device protocol version 

RESET 

Reset device 

SIGNAL? 

Read if input is valid 

SN? 

Read device serial number 

VERSION? 

Get device firmware version 

10.2.1 

Command Descriptions 

 

Command - 

#

 

Command Type - System-mandatory 

Command Name 

Permission 

Transparency 

Set: 

End User 

Public 

Get: 

Description 

Syntax 

Set:  

Protocol handshaking 

#

 

Get: 

Response 

~nn@

OK

␍␊

 

Parameters 

 

Response Triggers 

  

Notes 

Use to validate the Protocol 3000 connection and get the machine number 

Содержание TP-588D

Страница 1: ...USER MANUAL MODEL TP 588D HDBT to DVI HDMI Receiver P N 2900 300325 Rev 2 www kramerAV com...

Страница 2: ......

Страница 3: ......

Страница 4: ...1 The Setup 4 way DIP switch 11 6 2 Locking the EDID 11 6 3 LED Indicators 12 6 4 Resetting the Device to Factory Default Parameters 13 7 Wiring the TP RJ 45 Ethernet Connector 14 8 Technical Specific...

Страница 5: ...y defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Routers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty...

Страница 6: ...ference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables Do not secure the cables in tight bundles or roll the slack into tight c...

Страница 7: ...ected and recycled To comply with the WEEE Directive Kramer Electronics has made arrangements with the European Advanced Recycling Network EARN and will cover any costs of treatment recycling and reco...

Страница 8: ...588D you can also receive via the TP cable EDID Extended Display Information Data and DVI signals between the TP 588D and the transmitter HPD Hot Plug Detect signals from the display device to the sou...

Страница 9: ...n a 1U rack space using the optional RK 3T adapter Lockable EDID Kramer engineers have developed special twisted pair cables to best match our digital twisted pair products BC HDKat6a CAT 6 23 AWG cab...

Страница 10: ...2 About the Power over Ethernet Feature Power over Ethernet passes electrical power along with data on Ethernet cabling This allows a single cable to provide both data connection and electrical power...

Страница 11: ...cting the output to a non HDCP acceptor or after the acceptor is powered up then lights solid 4 HDMI OUT Connector Connect to the HDMI acceptor see Section 5 5 LED Lights green when there is a valid H...

Страница 12: ...audio signals 5 FACTORY RESET Button Press and hold for at least 5 seconds or press while performing a power cycle to reset the device to default settings see Section 6 4 6 HDBT IN RJ 45 TP Connector...

Страница 13: ...the power to each device Figure 3 Connecting the TP 588D HDBT to DVI HDMI Receiver To connect the TP 588D as illustrated in the example in Figure 3 1 Connect the HDBT Out RJ 45 connector on the transm...

Страница 14: ...n 5 1 Connecting a Device to the TP 588D via RS 232 To connect a serial device to the TP 588D for data or control From the RS 232 9 pin D sub serial port on the remote device connect Pin 5 to the GND...

Страница 15: ...when the input signal is lost Off Always on no shutdown up default On 5 minutes down 4 Extra Range Enables disables the extra range function Off Disabled up default On Enabled down 6 2 Locking the ED...

Страница 16: ...r is powered up then lights solid DVI acceptor present but acceptor does not support HDCP 6 3 2 HDMI Out LED HDMI Out LED Color HDMI Signal State Green HDMI acceptor present Flashes 10 times immediate...

Страница 17: ...k not valid 6 4 Resetting the Device to Factory Default Parameters To reset the device to factory default parameters 1 Press and hold the Reset button on the rear panel of the device 2 Power cycle the...

Страница 18: ...t Using a TP cable that is incorrectly wired may cause permanent damage to the device Do not use unshielded TP cables with this product Figure 6 defines the TP pinout using a straight pin to pin cable...

Страница 19: ...ink Power Link POWER CONSUMPTION 12V DC 770mA OPERATING TEMPERATURE 0 to 40 C 32 to 104 F STORAGE TEMPERATURE 40 to 70 C 40 to 158 F HUMIDITY 10 to 90 RHL non condensing COOLING Convection vents ENCLO...

Страница 20: ...9 Network Mask 255 255 0 0 Gateway 0 0 0 0 UDP Port 50000 TCP Port 5000 8 1 3 Supported Resolutions 640x480p 85Hz 640x480p 75Hz 640x480p 72Hz 640x480p 60Hz 640x480p 59 95Hz 720x480p 60Hz 720x576p 50Hz...

Страница 21: ...0x1080p 60Hz 1920x1080i 50Hz 1920x1080i 60Hz 1600x1200p 60Hz 1600x900p 60Hz 1152x864p 75Hz 1440x900p 60Hz 1680x1050p 60Hz 1360x768p 60Hz 1366x768 60Hz 1366x768 50Hz 1400x1050p 60Hz 720x480i 30Hz 3840x...

Страница 22: ...d Not supported GTF standard Not supported Additional descriptors None Preferred timing Yes Native preferred timing 1280x720p at 60Hz 16 10 Modeline 1280x720 74 250 1280 1390 1430 1650 720 725 730 750...

Страница 23: ...h rate Hz 1000 1001 CE vendor specific data VSDB IEEE registration number 0x000C03 CEC physical address 1 0 0 0 Maximum TMDS clock 165MHz CE speaker allocation data Channel configuration 2 0 Front lef...

Страница 24: ...Command string with only one command without addressing Start Body Delimiter Command SP Parameter_1 Parameter_2 CR 10 1 1 2 Command String Formal syntax with command concatenation and addressing Star...

Страница 25: ...d ends with a message closing character Note A string can contain more than one command Commands are separated by a pipe character Message starting character For host command query For device response...

Страница 26: ...s X Refer to the controller manual 10 1 5 Command Forms Some commands have short name syntax in addition to long name syntax to allow faster typing The response is always in long syntax 10 1 6 Chainin...

Страница 27: ...E RST Reset machine name to factory default DNS NET DHCP Set DHCP mode NET GATE Set gateway IP NET IP Set IP address NET MAC Get MAC address NET MASK Set subnet mask PROT VER Read device protocol vers...

Страница 28: ...Notes Command DISPLAY Command Type System Command Name Permission Transparency Set Get DISPLAY End User Public Description Syntax Set Get Get output HPD status DISPLAY out_id Response nn DISPLAY out_i...

Страница 29: ...ortType ETHPort Parameters portType TCP UDP ETHPort TCP UDP port number Response Triggers Notes Command EDID CS Command Type EDID Handling Command Name Permission Transparency Set EDID CS End User Pub...

Страница 30: ...HDCP MOD End User Public Description Syntax Set Set HDCP mode HDCP MOD inp_id mode Get Get HDCP mode HDCP MOD stage_id Response Set Get nn HDCP MOD stage_id mode Parameters inp_id input number 1 max n...

Страница 31: ...ore execution Get command was received Response is sent to all com ports after execution if HDCP STAT was set by any other external control device button press device menu and similar or HDCP mode cha...

Страница 32: ...Ethernet Command Name Permission Transparency Set NAME Administrator Public Get NAME End User Public Description Syntax Set Set machine DNS name NAME machine_name Get Get machine DNS name NAME Respon...

Страница 33: ...P Administrator Public Get NET DHCP End User Public Description Syntax Set Set DHCP mode NET DHCP mode Get Get DHCP mode NET DHCP Response nn NET DHCP mode Parameters mode 0 Do not use DHCP Use the IP...

Страница 34: ...otes A network gateway connects the device via another network and maybe over the Internet Be careful of security problems For proper settings consult your network administrator Command NET IP Command...

Страница 35: ...X is hex digit Response Triggers Notes Command NET MASK Command Type Communication Command Name Permission Transparency Set NET MASK Administrator Public Get NET MASK End User Public Description Synta...

Страница 36: ...where X is a decimal digit Response Triggers Notes Command RESET Command Type System mandatory Command Name Permission Transparency Set RESET Administrator Public Get Description Syntax Set Reset devi...

Страница 37: ...ggers After execution a response is sent to the com port from which the Get was received Response is sent after every change in input signal status ON to OFF or OFF to ON Notes Command SN Command Type...

Страница 38: ...80x720p 59 94Hz 60Hz 5 1920x1080i 59 94Hz 60Hz 6 720 1440 x480i 59 94Hz 60Hz 7 720 1440 x480i 59 94Hz 60Hz 8 720 1440 x240p 59 94Hz 60Hz 9 720 1440 x240p 59 94Hz 60Hz 10 2880x480i 59 94Hz 60Hz 11 2880...

Страница 39: ...p 100Hz 42 720x576p 100Hz 43 720x576p 100Hz 44 720 1440 x576i 100Hz 45 720 1440 x576i 100Hz 46 1920x1080i 119 88 120Hz 47 1280x720p 119 88 120Hz 48 720x480p 119 88 120Hz 49 720x480p 119 88 120Hz 50 72...

Страница 40: ...served 10 3 4 EDID Source Number Value 0 Input 1 Output 2 Default EDID 10 3 5 Signal Validation Number Value 0 Signal or sink is not valid 1 Signal or sink is valid 2 Sink and EDID is valid 10 3 6 HDC...

Страница 41: ......

Страница 42: ...re opening andservicing For the latest information on our products and a list of Kramer distributors visit our Web site to find updates to this user manual We welcome your questions comments and feedb...

Отзывы: