24
TP-588D - Protocol 3000
Command -
BUILD-DATE
Command Type - System-mandatory
Command Name
Permission
Transparency
Set:
-
-
-
Get:
BUILD-DATE?
End User
Public
Description
Syntax
Set:
Get device build date
#
BUILD-DATE
␍
Get:
-
-
Response
~nn@
BUILD-DATE
␠
date
␠
time
␍␊
Parameters
date
-
Format: YYYY/MM/DD where YYYY = Year, MM = Month, DD = Day
time
-
Format: hh:mm:ss where hh = hours, mm = minutes, ss = seconds
Response Triggers
Notes
Command -
DISPLAY?
Command Type - System
Command Name
Permission
Transparency
Set:
-
-
-
Get
DISPLAY?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get output HPD status
#
DISPLAY?
␠
out_id
␍
Response
~ nn@
DISPLAY
␠
out_id,status
␍␊
Parameters
out_id -
output number
status
- HPD status according to signal validation
Response Triggers
After execution, response is sent to the com port from which the Get was received
Response is sent after every change in output HPD status ON to OFF
Response is sent after every change in output HPD status OFF to ON and ALL parameters (new EDID,
etc.) are stable and valid
Notes