Kramer Electronics Ltd.
PA-120Net, PA-240Net
– Protocol 3000
29
MODEL?
Functions
Permission
Transparency
Set:
–
–
–
Get:
MODEL?
End User
Public
Description
Syntax
Set:
–
–
Get:
Get device model
#MODEL?
CR
Response
~
nn
@MODEL
SP
model_name
CR LF
Parameters
model_name
– string of up to 19 printable ASCII chars
Notes
This command identifies equipment connected to Step-in master products and notifies of identity changes
to the connected equipment. The Matrix saves this data in memory to answer REMOTE-INFO requests
K-Config Example
“#MODEL?”,0x0D
PROT-VER?
Functions
Permission
Transparency
Set:
–
–
–
Get:
PROT-VER?
End User
Public
Description
Syntax
Set:
–
–
Get:
Get device protocol version
#PROT-VER?
CR
Response
~
nn
@PROT-VER
SP
3000:version
CR LF
Parameters
version
– XX.XX where X is a decimal digit
K-Config Example
“#PROT
-
VER?”,0x0D
RESET
Functions
Permission
Transparency
Set:
RESET
Administrator
Public
Get:
–
–
–
Description
Syntax
Set:
Reset device
#RESET
CR
Get:
–
–
Response
~
nn
@RESET
SP
OK
CR LF
Notes
To avoid locking the port due to a USB bug in Windows, disconnect USB connections immediately after
running this command. If the port was locked, disconnect and reconnect the cable to reopen the port.
K-Config Example
“#RESET”,0x0D