Kramer Electronics Ltd.
PA-120Net, PA-240Net
– Protocol 3000
36
AUD-STANDBY
Functions
Permission
Transparency
Set:
AUD-STANDBY
End User
Public
Get
AUD-STANDBY?
End User
Public
Description
Syntax
Set:
Set standby mode
#AUD-STANDBY
SP
StandbyMode
,
TimeDelay
CR
Get:
Get standby mode state
#AUD-STANDBY?
CR
Response
~
nn
@AUD-STANDBY
SP
StandbyMode
,
TimeDelay
CR LF
Parameters
StandbyMode
–
0
(Off),
1
(Delayed, auto mode),
2
(Standby mode)
TimeDelay
–
5
,
10
, or
15
(time delay [min] to standby mode)
Notes
Active only in auto mode
K-Config Example
Set the standby delay time to 10 minutes:
“#AUD
-
STANDBY 1,10”,0x0D
BALANCE
Functions
Permission
Transparency
Set:
BALANCE
End User
Public
Get:
BALANCE?
End User
Public
Description
Syntax
Set:
Set balance level
#BALANCE
SP
channel
,
balancelevel
CR
Get:
Get balance level
#BALANCE?
SP
channel
CR
Response
~
nn
@BALANCE
SP
channel
,
balance_level
CR LF
Parameters
channel
–
1
(Speaker output),
2
(Line level output)
balancelevel
–
-15
to
+15
(audio parameter in Kramer units, minus sign precedes negative values)
++ increase current value
-- decrease current value
K-Config Example
Set the speaker output balance to +12:
“#BALANCE 1,12”,0x0D