Kramer Electronics Ltd.
PA-120Net, PA-240Net
– Defining the PA-240Net and PA-120Net Power Amplifier
5
#
Feature
Function
Dante RJ-45 Port
Connect to the
Dante™ audio source via the Network. By default, DHCP
is enabled.
AUDIO IN
Balanced/Unbalanced
Stereo Audio 5-pin
Terminal Block Connector
Connect to a line-level, balanced/unbalanced, stereo audio source.
LINE OUT Balanced
Stereo Audio 5-pin
Terminal Block Connector
Connect to a balanced, stereo audio acceptor (for example, amplified
speakers).
FACTORY DEFAULT
Button
Press to return to the factory default settings, including all the
configurations and network settings.
VOLUME Attenuator
Master volume for speaker output
– rotate to set the maximum amplifier
volume.
ETHERNET RJ-45
Connector
Connect to an ETHERNET LAN to control the
PA-240Net
via built-in web
page. By default, IP is fixed at 192.168.1.39.
RS-232 (G, Tx, Rx) Port
Connect to an RS-232 connector on AV equipment or a PC or other
Serial Controller.
Hi-Z/Lo-Z and 100V/70V
DIP-Switches
DIP-Switch 1: Set to Hi-Z for high impedance or Lo-Z for low impedance.
DIP-Switch 2: In Hi-Z mode, select 70V or 100V operation.
Lo-Z and Hi-Z Speaker
Output Terminal Block
Connector
Lo-Z
– Connect left +, left -, right +, and right - to Lo-Z (4Ω or 8̙Ω)
speakers.
Hi-Z
– connect Hi-Z and COM to 70V or 100V Hi-Z speakers.
In Hi-Z mode, the output is mono and can be selected via webpage
– Left
channel to mono, or stereo to mono summing
Power Connector with
Fuse
AC connector, enabling power supply to the unit.
Mains Power Switch
Switch for turning the device on or off.