Kramer Electronics Ltd.
FC-7P
– Kramer Protocol 3000
52
SN
Functions
Permission
Transparency
Set:
-
-
-
Get:
SN?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get device serial number
#SN?CR
Response
~nn@SNSP
serial_number
CR LF
Parameters
serial_number
– 11 decimal digits, factory assigned
Response Triggers
Notes
This device has a 14 digit serial number, only the last 11 digits are displayed
K-Config Example
“#SN?”,0x0D
TIME
Functions
Permission
Transparency
Set:
TIME
Administrator
Public
Get:
TIME?
End User
Public
Description
Syntax
Set:
Set device time and date
#TIMESP
day_of_week,date,time
CR
Get:
Get device time and date
#TIME?CR
Response
~nn@TIMESP
day_of_week,date,time
CR LF
Parameters
day_of_week
– one of:
SUN
,
MON
,
TUE
,
WED
,
THU
,
FRI
,
SAT
date
– format:
DD-MM-YYYY
time
– format:
hh:mm:ss
Response Triggers
Notes
The year must be 4 digits
The device does not validate the day of week from the date
Time format
– 24 hours
Date format
– Day, Month, Year
K-Config Example
Set the time to 09:45, Tuesday, 01-July-2015:
“#TIME TUE,01
-07-
2015,09:45:00”,0x0D