– Using Embedded Web Pages
21
The relay ports have the following characteristics:
•
Rated at 30V DC and 1A
•
Default state of normally open
•
A non-latching relay function, that is, the contact is left open when unpowered or on
power up state. This means that if a relay is closed and power is lost, the relay returns to
its default state. To return it to its pre-power loss state, the setting must be changed
using either the Web UI or a P3000 command
To close a relay, (for example, relay 2)
:
1. On the Relay Setting page, click Port button 2 to select the second relay.
The current relay status is shown to the right of the button.
2. Click Close.
The relay closes, the button changes color, and the Relay 2 LED on the front panel lights
green.
When DIP-switches 1 and 2 are set up to GPIO, Relay ports 1 through 4 are grayed out and
the following Relay port settings screen appears:
Activating Security
The Security page allows you to turn logon authentication on or off.
Figure 19: Security Page