Kramer Electronics Ltd.
FC-7P
– Kramer Protocol 3000
50
RELAY-STATE
Functions
Permission
Transparency
Set:
RELAY-STATE
End User
Public
Get:
RELAY-STATE?
End User
Public
Description
Syntax
Set:
Set relay state
#RELAY-STATE
␠
RelayNumber,RelayState
␍
Get:
Get relay state
#RELAY-STATE?
␠
RelayNumber
␍
Response
~nn
@RELAY-STATE
␠
RelayNumber,RelayState
␍␊
Parameters
RelayNumber
– relay number:
1-2
RelayState
– relay state
0
(open),
1
(close)
Response Triggers
Notes
K-Config Example
Close relay 2:
“#RELAY
-
STATE 2,1”,0x0D
PROT-VER
Functions
Permission
Transparency
Set:
-
-
-
Get:
PROT-VER?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get device protocol version
#PROT-VER?CR
Response
~nn@PROT-VERSP3000:
version
CR LF
Parameters
version
– XX.XX where X is a decimal digit
Response Triggers
Notes
K-Config Example
“#PROT
-
VER?”,0x0D