Operating Instructions
OIE 15en Edition 2019-12 HW 2.0/SW 2.0
19
Connection assignments
Electrical connection
Connection assignments
Pick ups
Analog outputs
The data logger can be connected to the analog outputs 4–20 mA, see "Data acquisition accessories",
page 41.
Pulse outputs
The data logger can be connected to these connections, see "Data acquisition accessories", page 41.
Power supply 24 V DC
Different power supply units are available as accessories, see "Accessories electrical connection",
page 39. These are connected here.
Serial interface
Connection
Function
Terminal
Pick up 1
U+24 V DC
12
Signal
13
Gnd
14
Pick up 2
(+ 90°)
U+24 V DC
15
Signal
16
Gnd
17
Connection
Function
Terminal
Analog output 1 4–20 mA
Signal
3
Gnd
4
Analog output 1 0–10 V
Signal
5
Gnd
6
Connection
Function
Terminal
Pulse output 1
Signal
20
Gnd
21
Connection
Terminal
+24 V DC
1
Gnd
2
Interface
Function
Terminal
RS 485
A
10
B
11
RS 232
TxD
7
RxD
8
Gnd
9
Содержание BEM 300 Series
Страница 1: ...Operating Instructions KRAL Electronics BEM 300 Series OIE 15en Edition 2019 12 HW 2 0 SW 2 0 ...
Страница 45: ...Operating Instructions OIE 15en Edition 2019 12 HW 2 0 SW 2 0 45 Notes Appendix Notes ...
Страница 46: ...46 OIE 15en Edition 2019 12 HW 2 0 SW 2 0 Operating Instructions Notes Appendix Notes ...
Страница 47: ...Operating Instructions OIE 15en Edition 2019 12 HW 2 0 SW 2 0 47 Notes Appendix Notes ...
Страница 48: ...www kral at KRAL GmbH 6890 Lustenau Austria Tel 43 5577 86644 0 E Mail kral kral at ...