12
OIE 15en Edition 2019-12 HW 2.0/SW 2.0
Operating Instructions
Installation
Installation and removal
Installation in the control cabinet
The electronic unit can be mounted in control cabinets having a sheet thickness of 0.5 – 5 mm by using
the supplied mounting frame. The mounting frame consists of a front frame
2
and a sealing frame
4
Fig. 2, page 12.
When the space is limited, mounting is also possible without a housing cover
6
and gasket with cable
entries
5
Required minimum mounting depth: 80 mm
Dimensions of front frame:
□
Height: 145 mm
□
Width: 145 mm
□
Depth: 12 mm
Aids:
□
KRAL tool set
1
Electronic unit
2
Front frame
3
Control cabinet
4
Sealing frame
5
Seal with cable
entries
6
Housing cover
Fig. 2
Control cabinet mounting BEM 500
a
117 mm
b
117 mm
Fig. 3
Control cabinet section
1
2
3
4
5
6
a
b