40
KPS-MT50 • Digital multimeter
ENG
4.2.7 Transistor
Range
Description
Test condition
hFE
Display read approx. HFE
value (0-1000) of transistor
under test (all type).
Base Current approx.
10μA, Vce approx. 2.8V.
4.2.8 Temperature
Range
Resolution
Accuracy
-20ºC~0ºC
1ºC
±(5,0% of r4 digits)
1ºC~400ºC
±(1,0% of r3 digits)
401ºC~1000ºC
2,0% of reading
Overload protection: fuse (FF400mA/1000V).
Temperature specifications do not include thermocouple errors.
4.2.9 Capacitance
Range
Resolution
Accuracy
40nF
0,01nF
±(4,0% of r5 digits)
400nF
0,1nF
4µF
0,001µF
40µF
0,01µF
400µF
0,1µF
4000µF
1µF
Overload protection: 250V dc or 250V ac rms