![KPS KPS-MT50 Скачать руководство пользователя страница 39](http://html.mh-extra.com/html/kps/kps-mt50/kps-mt50_instruction-manual_1999998039.webp)
39
KPS-MT50 • Digital multimeter
ENG
4.2.4 Resistance
Range
Resolution
Accuracy
400Ω
0,1Ω
± (0,8% of r3 digits)
4kΩ
1Ω
± (0,8% of r1 digit)
40kΩ
10Ω
400kΩ
100Ω
4MΩ
1kΩ
40MΩ
10Ω
± (1,0% of r2 digits)
Overload protection: 250V dc or 250Vac rms.
Open Circuit Voltage: Less than 700mV..
4.2.4 Diode
Range
Resolution
Accuracy
1mV
Display read approx. forward voltage of
diode
Forward DC Current: approx. 1mA
Reversed DC Voltage: approx. 2.8V
Overload protection: 250Vdc or 250Vac rms.
4.2.6 Audible continuity
Range
Continuity beeper
≤60Ω