Kozy-World KWN111 Скачать руководство пользователя страница 18

1 8

PARTS  LIST

KWN111

This  list  contains  replaceable  parts  for  your  heater.  When  ordering  replacement
parts, follow   the  instructions  listed under  

Replacement  Parts

  on  page 16  of  this

manual.

KEY

NO.

1

2
3
4
5

5-1
5-2

6
7
8
9

10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

 PART

NUMBER

MB10008

MB09003
ML006-01
MB19005
ND1206x600x9
ND0803-6
ND0807-B2
ML026-02
ML069-02
NV2020-14
ML122-01
ML073-01
ML029-01
MB40033
MB40034
MB40035
MB40036
ML090-03
MB16002
NRV81FI-6
96-4Z
ML079-01
ML119-01
MB29003
ML060-02
ML083-03

MB28001
ML070-01W

DESCRIPTION

Cabinet   Assembly

Lower  Front  Panel  Assembly
Reflector  Unit
Burner   Assembly
ODS  pilot   Assembly
Thermocouple
Ignitor  Electrode
ODS  Mounting  Bracket
Self  Tapping  Screws
Control   Valve
Brass   Cap
Ignitor   line
Control   Valve  Fixed  Nut
Main  Inlet  Tube  Assembly
ODS   Gas  Line  Assembly
Burner    Gas   Line   Assembly  A
Burner    Gas   Line   Assembly  B
Injector
Control  Knob  Assembly
Pressure   Regulator
Washer
Self  Locking  Screws
Pressure  Tap
Grill   Guard
Mounting  Bracket
lgnitor  Assembly

Assembly  Hardware
CSA/AGA   Label

QTY

1

1
1
1
1
1
1
1

10

1
1
1
1
1
1
1
1
2
1
1
2
2
1
1
1
1

1
1

PARTS  AVAILABLE  NOT  SHOWN

Содержание KWN111

Страница 1: ...only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufactur...

Страница 2: ...ARNING Do not use any accessory not approved for use with this heater WARNING Any change to this heater or its controls can be dangerous 1 This appliance is only for use with the type of gas indicated...

Страница 3: ...r with care Follow all local codes In the absence of local codes use the latest edition of National Fuel Gas Code ANSZ223 1 also known as NFPA 54 Available from American National Standards Institute I...

Страница 4: ...ods described in the National Fuel Gas Coda ANS Z223 1 Section 5 3 or applicable local codes Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for c...

Страница 5: ...n the space Vent free heater Btu Hr Gas water heater Btu Hr Gas furnace Btu Hr Vented gas heater Btu Hr Gas Fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Do not include direct vent ga...

Страница 6: ...toff valve l ground joint union l test gauge connection l sediment trap l tee joint l pipe wrench A CSA AGA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to te...

Страница 7: ...ne of two ways 1 Attaching to wall stud 2 Attaching to wall anchor Attaching to Wall Stud This method provides the strongest hold Insert mounting screws through mounting bracket and into wall studs At...

Страница 8: ...taching Mounting Bracket To Wall Note Wall anchors mounting screws and spacers are in hardware package The hardware package is provided with heater Attaching to Wall Stud Method For attaching mounting...

Страница 9: ...p is an acceptable alternative to test gauge connection Purchase the optional CSA AGA design certified equipment shutoff valve from your dealer See Accessories page 16 IMPORTANT Install an equipment s...

Страница 10: ...alve see Figure 13 2 Open main gas valve located on or near gas meter 3 Make sure control knob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to control valve see Fig...

Страница 11: ...ob slightly and rotate counterclockwise Release the downward pressure on the knob while continuing to turn until the knob locks at the desired setting position Do not operate between locked positions...

Страница 12: ...the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if compressed air is not available Figure 22 Pilot Air Inlet Hole CABINET Air Passageways l Use a vacuum...

Страница 13: ...sed in 2 Control knob is not pressed in long enough 3 Equipment shutoff valve is not fully open 4 Thermocouple connection is loose at control valve 5 Pilot flame is not touching thermocouple This allo...

Страница 14: ...ked positions 1 Residues from manufacturing processes 1 Metal is expanding while heating or contracting while cooling 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into w...

Страница 15: ...natural gas company 3 Clean ODS pilot see Cleaning page 12 1 Locate and correct all leak s see Checking Gas Connections page 10 2 Replace control valve 1 Take apart gas tubing and remove foreign matt...

Страница 16: ...en Gas Pressure Is Too Low l Pilot will not stay lit l Burner will have delayed ignition l Heater will not produce specified heat When Gas Quality Is Bad l Pilot will not stay lit l Burner will produc...

Страница 17: ...1 7 ILLUSTRATED PARTS BREAKDOWN KWN111...

Страница 18: ...4Z ML079 01 ML119 01 MB29003 ML060 02 ML083 03 MB28001 ML070 01W DESCRIPTION Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly ODS pilot Assembly Thermocouple Ignitor Electrod...

Отзывы: